Home | Manufacturer Directory | UPC Lookup | Wanted Manuals | Information Pages |
Register Login | Members Area |

Back To Craftsman Air Compressor       Model: 921.166400 or 921166400 Craftsman 12 Gallon 1 HP Air compressor
Regular Text Search or Search by Model Number

Register / log-in to add to your Hammerwall Collection.
Manual Location


Upload a pic of this item

Manuals For Same Model Number.
No other Manuals with the Exact Same Model Number and Manufacture.
Other Items that are in the Same Category.
919.152120 Craftsman Permanenty Lubricated Tank Mounted Ai...
919.165610 Craftsman Permanently Lubricated 2 Stage Twin V...
919.152350 Craftsman Permanently Lubricated Compact Air Co...
919.728000 Sears Craftsman Tank Mounted Air Compressor Man...
919.167241 Craftsman Permanently Lubricated Tank Mounted A...
919.152143 Craftsman Permanently Lubricated Tank Mounted A...
919.167462 Craftsman Permanently Lubricated Single Stage S...
919.165361 Craftsman Permanently Lubricated Portable Air C...
919.165381 Craftsman Permanently Lubricated Portable Air C...
919.167242 Craftsman Permanently Lubricated Tank Mounted A...

This is a partial text extraction from the pdf, to download the pdf, click the Manual tab. If you want to search this text, hold control and F, and type the word you are looking for.

Page: 1

Owner's Manua _ AiR COMPRESSOR 12 - gaHton 1 OiJ Lubricated Mode _ No . 921.1 { $ 6400 o Safety instructions Before using this product , installation & Operation read this manuan and follow Maintenance & Storage ati its Safety Runes and Troubleshooting Guide Parts List Operating instructions . , , EspaSon , p . 10 Sears , Roebuck and Co . , Hoffman Estates , IL 60179 U . S . A . www . sears . com 5 / 20 / 2005 Part No . E101338
Page: 2

TABLE OF CONTENTS Page Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . See BeUow Safety SymboUs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Umportant Safety Unstructions & Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 GUossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Duty Cycle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Parts & Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 UnstaHation & AssembUy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Operating Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Troubleshooting Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Expbded View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Espa _ oU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 ONE YEAR FULL WARRANTY ON CRAFTSMAN AIR COMPRESSOR Ufthis Craftsman Air Compressor falls due to a defect in materiaU or workmanship within one year from the date of purchase , RETURN UTTO ANY SEARS STORE OR PARTS AND REPAIR CENTER OR OTHER CRAFTSMAN OUTLET UNTHE UNUTED STATES FOR FREE REPAIR , Ufthis Craftsman Air Compressor is used for commerdaU or rentaUpurposes , this warranty applies for onUy90 days from the date of purchase , This warranty gives you specific UegaUrights and you may aUsohave other rights which vary from state to state , Sears , Roebuck and Co . , Dept . 817WA , Hoffman Estates , IL 60179
Page: 3

Safety Symbols The information listed below should be read and understood by the operator , This information is given to protect the user while operating and storing the air compressor , We utilize the symbols below to allow the reader to recognize important information about their safety , indicates an imminently hazardous situation which , if indicates a potentially hazardous situation which , if not not avoided , wiii result in death or serious injury , avoided , may result in minor or moderate injury , indicates a potentially hazardous situation which , if not When used without the safety alert symbol indicates avoided , could result in death or serious injury a potentially hazardous situation which , if not avoided , may result in property damage , mmpottant Safety mnstructions and Guidelines Save aH instructions improper operation or maintenance of this product could result in serious injury and / or property damage , Read and understand all of the warnings and safety instructions provided before using this equipment , The air compressor should be operated on a dedicated 15 amp circuit , if the circuit does not have 15 free amps available , a larger circuit must be used , Always use more air hose before utilizing extension cords , All extension cords used must be 12 gauge with a maximum length of 25 ft , The circuit fuse type must be a time delay , Low voltage could cause damage to the motor , if the air compressor is in operation , all guards and covers should be attached or Risk of Moving Parts installed correctly , if any guard or cover has been damaged , do not operate the equipment until the proper personnel has correctly repaired the equipment , The power cord should be free of any moving parts , twisting and / or crimping while in use and while in storage , Risk of Burns There are surfaces on your air compressor that while in operation and thereafter can cause serious burns if touched , The equipment should be allowed time to cool before any maintenance is attempted , items such as the compressor pump and the outlet tube are normally hot during and after operation , Operation of the air compressor should always be in a position that is stable , Never Risk of Falling use the air compressor on a rooftop or elevated position that could allow the unit to fall or be tipped over , Use additional air hose for elevated jobs , Always wear ANSi Z87 , 1 approved safety glasses with side shields when the air Risk from Flying Objects compressor is in use , Turn off the air compressor and drain the air tank before r , i performing any type of maintenance or disassembly of the hoses or fittings , Never point any nozzle or sprayer toward any part of the body or at other people or animals , 1
Page: 4

important Safety instructions & Guidefines Risk of Breathing Avoid using the air compressor in confined areas , Always have adequate space ( 12 inches ) on all sides of the air compressor , Also keep children , pets , and others out of the area of operation , This air compressor does not provide breathable air for anyone or any auxiliary breathing device , Spraying material wiii always need to be in another area away from the air compressor to not allow intake air to damage the air compressor filter , Risk of Never utilize the air compressor in the rain or wet conditions , Any electrical issues or repairs should be performed by authorized personnel such as an electrician and E _ ectrica _ Shock should comply with all national and local electrical codes , The air compressor should also have the proper three prong grounding plug , correct voltage , and adequate fuse protection , Risk of Never operate the compressor near combustible materials , gasoline or solvent vapors , if spraying flammable materials , locate the air compressor at bast 20 feet away from E × p _ osion or Fire the spray area , Never operate the air compressor indoors or in a confined area , Risk of Bursting Always drain the air compressor tank daily or after each use , if the tank develops a leak , then replace the air compressor , Never use the air compressor after a leak has been 1 found or try to make any modifications to the tank , Never modify the air compressor's factory settings which control the tank pressure or any other function , Specifications Pump . . . . . . . . . . . . . . . . . . . . . . . . . . Oil - lube direct drive AirTank Capacity . . . . . . . . . . . . . . . . . . . . . . . . 12 Gallons Cutqn Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95 PSi Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . 1,0 HP ( induction ) Cut - out Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . 125 PSi Bore . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1,65 " SCFM @ 90 PSi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2,4 Stroke . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1,26 " Oil Capacity . . . . . . . . . . . . . . . . . . . . . . . . . 90 mL or 3 oz , Voltage Single Phase . . . . . . . . . . . . . . . . . . . . . . . 120 VAC Minimum Circuit Requirement . . . . . . . . . . . . . . . . 15 Amps Oil Type . . . . . . . . . . . . . . . . . . . . . . . . . SAE 30 Non - detergent G ossary CFM : Cubic feet per minute , Cut - Out Pressure : The point at which the motor stops when the tank has reached maximum air SCFM : Standard cubic feet per minute ; a unit of measure for air delivery , pressure , PSI ¢ : Pounds per square inch gauge ; a unit of measure Code Certification : Products that bear one or more of for pressure , the following marks : UL , ULc , ETL , CSA , have ASME : American Society of Mechanical Engineers , been evaluated by OSHA - certified independent safety laboratories and meet the applicable California Code : Unit may comply with California Code Underwriters Laboratories Standards for Safety , 462 ( I ) ( 2 ) / ( M ) ( 2 ) , Cut - In Pressure : The air compressor will automatically start to refill the tank when the pressure drops below the prescribed minimum , Duty Cycle This is a 50 % duty cycle air compressor , Do not run the air compressor more than 30 minutes of one hour , Doing so could damage the air compressor ,
Page: 5

Parts & Features See figures below for reference , f Provides clean air to the pump and must always indicates the reserve air pressure in the tank . I Tank Pressure Gauge be kept free of debris . Check on a daily basis or Air Intake Filter } before each use . Regulator Gauge indicates the outgoing air pressure to the tool and is controlled by the regulator . Quick Connect Offers a quick release feature for attaching and removing the air hose . Regulator The air pressure coming from the air tank is controlled by the regulator , @ Oil Fill Cap To increase the pressure , turn the knob clockwise and to decrease the pressure turn the knob counterclockwise , Tank Safety Valve Sight Gauge Used to allow excess tank pressure to escape valve should only open when the tank pressure is above the maximum rated pressure . Tube Pressure Switch This controls the power to the motor and also the cutdn / cut - out pressure settings . This switch serves as the Auto - On / Off positions for the unit . Pressure Relief Valve The pressure relief valve , located on the side of the pressure switch , is designed to automatically release compressed air when the air compressor reaches cut - out pressure . The released air should only escape momentarily and the valve should then close . Pressure Relief Tube Check Valve When the pump is not in operation , the valve closes to retain air pressure inside the tank . An internal component .
Page: 6

Installation & Assembly The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes The air compressor should be turned off , unplugged from and ordinances , Check with a qualified electrician or the power source , the air bled from the tank and the unit service personnel if these instructions are not completely allowed time to cool before any maintenance is performed , understood or if in doubt as to whether the tool is properly Personal injuries could occur from moving parts , electrical grounded , sources , compressed air or hot surfaces , The quick connect assembly must be attached before use , Failure to assemble correctly could result in leaks and possible injury , if unsure of assembly instructions or you experience difficulty in the assembly please call our toll free number installation of the grounding plug wiii result in for assistance , a risk of electric shock , if repair or replacement of the cord or plug is necessary , do not connect the grounding wire to either fiat blade terminal , The wire with insulation Assembly 1 , Remove air compressor , manual , air filter assembly , having an outer surface that is green with or without and accessories from packaging , yellow stripes is the grounding wire , Check with a qualified 2 , Remove the plastic plug from the compressor intake electrician or serviceman if the grounding instructions are port , ( see diagram below ) not completely understood , or if in doubt as to whether 3 , Install the filter in the compressor intake port , the product is properly grounded , Do not modify the plug ( see diagram be ! ow ) provided , if it will not fit the outlet , have the proper outlet 4 , Remove the oil fiii cap from the crankcase and fiii until installed by a qualified electrician , the oil reaches the top of the red dot in the sight glass , Oil capacity is 3 oz , ( seebelow ) Use SAE ° 30 This product is for use on a circuit having a nominal rating non - detergent ( API CG / CD heavy duty motor oil ) , of 120 volts and is factory - equipped with a specific electric Under extreme cold weather conditions use SAE ° 10 cord and plug to permit connection to a proper electric weight oil , circuit , Make sure the product is connected to an outlet 5 , Replace the oil cap , having the same configuration as the plug , An adapter should not be used with this product , if the product must be reconnected for use on a different type of electric circuit , qualified service personnel should make the reconnection , Estimated Assembly Time : Approximately 5 minutes Extension Cords Use only a 3 ° wire extension cord that has a 3 ° blade Getting Started _ Location of the Air Compressor grounding plug and a 3 ° slot receptacle that will accept the The air compressor should always be located in a clean , plug on the product , Make sure your extension cord is in dry and well ventilated environment , The unit should have good condition , When using an extension cord , be sure to at minimum , 12 inches of space on each side , The air filter use one heavy enough to carry the current your product will draw , Cords must not exceed 25 feet and No , 12 AWG intake should be free of any debris or obstructions , Check the air filter on a daily basis to make sure it is size must be used , An undersized cord will cause a drop clean and in working order , in line voltage resulting in loss of power and overheating , Break In Procedures Grounding Instructions This product should be grounded , in the event of an No break in procedure is required by the user , electrical short circuit , grounding reduces the risk of This product is factory tested to ensure proper operation electric shock and performance , by providing an escape wire for the electric current , This product is equipped with a cord having a grounding wire with an appropriate grounding plug , ( See the figure below , ) Grounded Outlet Grounding Pin 4
Page: 7

Operating Procedures Dally Start - Up Procedures 6 , Plug the power cord into the proper receptacle , 1 , Set the Auto - On / Off lever to the Off position , 7 , Turn the Auto - On / Off [ ever to the On - Auto position and 2 , inspect the air compressor , air hose , and any the compressor wii [ start and build air pressure in the accessories / tools being used for damage or obstruction , tank to cut - out pressure and then shut off automatically , if any of these mentioned items are in need of repair / 8 , Adjust the regulator to a PSi setting that is needed for replacement , contact your local authorized service dealer your application and be sure it is within the safety before use , standards required to perform the task , if using a 3 , Close the drain valve , pneumatic too [ , the manufacturer should have 4 , Check the o11 [ eve [ of the pump , recommendations in the manual for that particular 5 , Connect the air hose to the quick connect socket on too [ on operating PSi settings , the regulator assembly by inserting the quick connect 9 , The air compressor is now ready for use , The following plug on the air hose into the quick connect socket , The inflation and cleaning accessories packaged with this quick connect socket collar wii [ snap forward and lock unit should only be operated at maximum pressure the plug into place providing an air tight sea [ between of 90PSi : blow gun , rubber - tapered nozzle , inflation the socket and plug , To release the air hose push the needles , adapter , and Mow gun adapter , collar back on the quick connect socket , Daily Shut - Down Procedures 1 , Set the Auto - On / Off [ ever to the Off position , 2 , Unplug the power cord from the receptacle , When draining the tank , always use ear and eye protection , 3 , Set the outlet pressure to zero on the regulator , Drain the tank in a suitable Iocationl condensation wiii be 4 , Remove any air tools or accessories , When draining present in most cases of draining , the tank , always use ear and eye protection , Drain the tank in a suitable location ; condensation wii [ be present in most cases of draining , 5 , Open the drain valve allowing air to bleed from the Water that remains in the tank during storage will corrode and weaken the air tank which could cause the tank to tank , After ai [ of the air has bled from the tank , dose the drain valve to prevent debris buildup in the valve , rupture , To avoid serious injury , be sure to drain the tank after each use or daily ,
Page: 8

Maintenance NOTE : Any service procedure not covered in the Before each use items to Check / Change maintenance schedule should be performed by or daily qualified service personnel X Check Tank Safety Valve Overall Unit Visual Check X The air compressor should be turned off , unplugged Check Air Filter X from the power source , air bled from the tank and Drain Tank X allowed time to coo [ before any maintenance is X Check Power Cord for Damage performed . after first 50 hours Change Oil after every 100 hours To ensure efficient operation and longer fife of the Check Oil Level X air compressor unit , a routine maintenance schedule should be followed . The following schedule is geared toward a consumer whose compressor is used in a normal working environment on a daily basis . Storage For storing the air compressor , be sure to do the following : 1 , Turn the unit off and unplug the power cord from the 4 , Open the drain valve to bleed ail air from the tank , 5 , Close the drain valve , receptacle , 2 , Remove ail air hoses , accessories , and air tools from 6 , Store the air compressor in a clean and dry location , the air compressor , 3 , Perform the daily maintenance schedule , Notes
Page: 9

Troubleshooting Guide The air compressor should be turned off and unplugged from the power source before any maintenance is performed as well as the air bled from the tank and the unit allowed time to cook Personal injuries could occur from moving parts , electrical sources , compressed air , or hot surfaces . PROBLEM POSSIBLE CORRECTION Air leaks at the check valve A defective check valve results in a constant air leak at the pressure relief valve or at the pressure relief valve , when there is pressure in the tank and the compressor is shut off . Drain the tank , then remove and clean or replace the check valve . Air leaks between head and Be sure of proper torque on head bolts , if leak remains , contact a service technician . cylinder . Air leak from safety valve . Operate the safety valve manually by pulling on the ring . if the valve continues to leak when in the closed position , it should be replaced . Pressure reading on the if there is an excessive amount of pressure drop when the accessory is used , regulated pressure gauge replace the regulator . drops when an accessory is used . NOTE : Adjust the regulated pressure under flow conditions ( while accessory is being used ) . it is normal for the gauge to show minimal pressure loss during initial use of the took Excessive tank pressure . Move the Auto - On / Off lever to the Off position , if the unit doesn't shut off , unplug it from the power source and contact a service technician , Motor wiii not start . Make sure power cord is plugged in and the switch is on . inspect for the proper size fuse in your circuit box . if the fuse was tripped , reset it and restart the unit . if repeated tripping occurs , replace the check valve or contact a service technician . Excessive moisture in the Remove the water in the tank by draining after each use . High humidity discharge air . environments wiii cause excessive condensation . Utilize water filters on your air line . NOTE : Water condensation is not caused by compressor malfunction . Be sure the compressor's air output is greater than your tool's air consumption rate . Air leaks from the tank body Never drill into , weld or otherwise modify the air tank or it will weaken . The tank can or tank welds . rupture or explode . Compressor cannot be repaired . Discontinue use of the air compressor .
Page: 10

Air Compressor Model 921.166400 Exploded View e2 _ / _ 49 48 _ \ \ 33 _ 40 46 43 _ _ . . . . . . 41 - - - - - 14
Page: 11

Air Compressor Mode 921.160400 Parts List PART # Ref , # Kit # PART DESCRmPTION QTY , Ref , # PART # Kit # PARTDESCRmPTION QTY . 1 Tank 1 Screw _ socket head , M6 x 1.0 x 30ram 4 40 2 Washer , Lock , 6mm 8 41 4Vasher , FHat , 6mm 4 3 E100227 IsoHator , Rubber 2 Cylinder head 1 42 E101037 4 E100809 Drain VaHve , 1 / 4 " NPT 1 Fitting , 9ODeg , 3 / 8 " NPT X 3 / 8 " Compression 1 43 E100098 5 Nut , Hex , MlO X 1.25 2 I Housinq , Air htake Fimter , DieCast I 44 6 E100435 1 Element , Air Filter 1 45 ¢ v ' asher , FHat ! , Omm 2 7 E101178 1 Cover , Air Filter 1 46 E101383 ¢ _ heeH , RedHub 2 8 2 Gasket , head 1 47 E101491 BoHt , ShouHder , MlOX 125 X 45 mm 2 9 Power Cord , 16 / 3 X 6 ' , ST 1 VaHvepilate 2 48 E101340 10 Valve , Reed 2 49 NippHe , 1 / 4 " NPT X 1.5 " 1 I1 Pressure switch I 2 Gasket , Vaive Hate I 50 E100957 12 2 Gasket , Cylinder , Upper 1 51 E100094 daHve , Safety 1 13 E101113 Cyiinder , iD 42ram X H 65mm 1 52 E100205 Pressure Gauge , 2 " , 200 PS _ I t4 NippHe , 1 / 4 " NPT X 1 " 1 Screw , SHCS , M6 X 1.0 X 20 mm 7 53 15 2 Gasket , Cylinder , Lower 1 54 E100059 ReguHator 1 16 Motor 1 55 E100093 Pressure Gauge , l . 5 " , 200 PSH 1 I7 Nut , M6 X 1.0 3 56 SoupHer , Quick - Connect I 18 3 Eccentric I 57 E101345 5 Tubing Cap , 20ram 2 19 5 HandHe I 3 Piston Assembly 1 58 2O 5 Rivet Nut , MSXO . 8 4 3 Ring , Scraper 1 59 2 ! 3 Ring , Compression 2 60 E101490 5 Handgrip 1 22 2 , 6 Baffle , Rubber 1 61 $ crew , Hex FHangeHead , M5 X 0.8 X lOmm 6 23 E100087 6 Oii Fill Cap I 62 E101137 Shroud , PHastic I 24 Manual 1 6 O - rinq , 2mm X 13.5 mm HD 1 Showf , NE ° 1 _ 01337 25 6 Cover , Crankcase 1 26 Screw , Hex FHangeHead , M5 X 0.8 X 15 mm 8 Note : OnHycomponents with a mistedpart / kit number are avaiHaNe . Descriptions 27 4,6 SeaH , OiHSight Gauge 1 are provided for reference onHy . The Kit # coHumndenotes the components 28 being offered as part of a kit . 4,6 Gauge , OiHSight t 29 Screw , SHCS , M8 X 1.25 X 16mm 4 30 Description ; Reference Numbers Washer , Lock , 8mm 4 Kit # . Part No , 31 Washer , FHat , 8mm 4 1 EI01179 Intake fiHterkit ; 5 , 6 , 7 32 Nut , Hex , M8 X 1.25 4 2 E100959 Gasket kit ; 8 , 11 , 12 , 15 , 22 33 8 Piston kit ; 18 , 19 , 20 , 2 ! NutrCompression , 3 / 8 " 2 3 E100251 34 8 FerruHe , Compression , 3 / 8 " 2 4 E100088 Sight gauge kit ; 27 , 28 35 8 Tube , Outlet 1 5 EI01489 HandHekit ; 57 , 58 , 59 , 60 36 EI0 ! 362 Check Valve 1 6 E101332 Crankcase cover kit ; 22 , 23 , 24 , 25 , 27 , 28 7 37 Pressure reHieftube kit ; 37 , 38 , 39 FerruHe , Compression , 1 / 4 " 2 7 E101481 38 7 Outlet tube kit ; 33 , 34 , 35 Nut , Compression , l / 4 " 2 8 E101480 39 7 Pressure RemiefTube 1
Page: 12

Contenido Pagina Garantia esta p _ . gina . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 SimboHos de segur [ dad Instrucciones y pautas de seguridad importantes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Especificaciones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 GIosario . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 C [ cHode trabajo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Partes y caracterist [ cas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Instalaci6n y ensambiaje . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Procedimientos de operaci6n . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Mantenimiento . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 AImacenamiento . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Diagn6stico y correcci6n de fallas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Lista de partes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 GARANTiA DE UN ANO PARA EL COMPRESOR DE AIRE CRAFTSMAN S [ este compresor de a [ re Craftsman HHegaa faHHadreb [ do a un defecto de manufactura o de materiaHes en un pHazode un a _ o , desde Hafecha de compra , DEVU ¢ : LVALO A LA THENDA U A OTRO CENTRO CRAFTSMAN 0 CENTRO DE SERVHCHOY PARTES SEARS EN LOS ESTADOS UNHDOS M , { S CERCANO para que sea reparado sin ningun cargo , Si este compresor de aire Craftsman se usa con fines comerciales o de renta , esta garantia unicamente se apiica por 90 dias a partir de Hafecha de compra . Esta garantia Heda derechos legales especificos ; adem6 . s , es posibie que usted tenga otros derechos , los cuales varian segun el estado . Sears , Roebuck and Co . , Dept . 8 ! 7WA , Hoffman Estates , IL 60179 10
Page: 13

S [ mbolos comunes de seguridad El operador debe leer y entender la informaci6n descrita a continuaci6n , Esta informaci6n se ofrece para proteger al usuario al operar y almacenar el compresor de aire , Los s [ mbolos siguientes son los que se utilizan para indicar al lector informaci6n que es importante para su seguridad , Indica una situaci6n de riesgo inminente que , al no Indica una situaci6n potencialmente peligrosa que , de no protegerse , provocar _ lesiones graves o la muerte . evitarse , podria provocar lesiones menores o moderadas , Indica una situaci6n potencialmente peligrosa que , al no Cuando no aparezca sin el simbolo de abrta de seguridad , protegerse , podria provooar lesiones graves o la muerte . 6sto quiere decir que hay'una situaci6n potencialmente peligrosa que , aI no protegerse , podria causar darios materiales , lnstrucciones y pautas de seguridad importantes , , Guarde todas las instrucciones , , La operaci6n y el mantenimiento inadecuados de este producto pueden provocar lesiones graves y daSos materiales . Antes de utilizar este equipo , lea y entienda las advertencias e instrucciones de seguridad aqui contenidas . El compresor de aire se debe operar desde un circuito especial de 15 amperios . Si el circuito no dispone de una capacidad de 15 amperios , se debe usar un circuito de mayor capacidad . Si es necesario , antes de emplear una extensi6n el @ trica , a _ ada una manguera de aire m _ s larga . Las extensiones el @ tricas deben set de calibre 12 y tenet una Iongitud maxima de 7,6 metros . El fusible deI circuito debe ser de acci6n retardada . Un voltaie demasiado baio puede da _ ar el motor . AI operar el compresor , todos los protectores y cubiertas deben estar fijados e Riesgo por partes en movimiento instalados correctamente . Si alguno de los protectores o cubiertas est _ da _ ado , no opere ei equipo hasta que personal calificado repare ei problema . Ei cable de corriente debe mantenerse alejado de las partes m6viles del equipo y no debe torcerse ni prensarse durante su empleo , ni al almacenarse . Riesgo de quemaduras En su compresor hay superficies que , al set tocadas durante y despues de su operaci6n , pueden causar quemaduras graves . Antes de darle mantenimiento al equipo , se debe dejar enfriar . Pot Io normal , durante y despues de su operaci6n , ciertas partes como la bomba del compresor y el tubo de salida estar _ n calientes . El compresor siempre debe ser operado en una posici6n estable . Nunca utilice el Riesgo de ca [ da compresor sobre un techo o en una posici6n elevada ya que podria caer o volcarse . AI trabajar en posiciones elevadas , utilice una manguera de aire ma . s larga . AI emplear el compresor , siempre utilice anteojos de seguridad con protectores Riesgo de lanzamiento laterales que cumplan con la norma ANSi Z87 . 1 . Antes de llevar a cabo cualquier de objetos clase de mantenimiento y antes de desconectar las mangueras y los acopladores , apague el compresor y drene el tanque de aire . Nunca apunte la boquilla o el rociador hacia ninguna parte de su cuerpo , ni el de otros seres . 11
Page: 14

instrucciones y pautas de seguridad importantes Evite utHizar eUcompresor de aire en areas encerradas , Sbmpre tenga un espacio Riesgo para la Hbre adecuado ( 30 cm , ) en todos bs UadosdeUcompresor , Tambi6n mantenga fuera respiraci6n deU _ . rea de operaci6n a Uasmascotas , nifios y otras personas , Este compresor de aire no provee aire que pueda ser respirado ni empbado con un disposWvo respiratorio auxHiar , EUmateriaU de rociado sbmpre debera estar en otra zona , abjado del compresor de aire , para evitar que el aire aspirado dafie al filtro del compresor , Nunca utilice el compresor de aire bajo Iluvia o en lugares mojados , Los probbmas Rbsgo de el6 . ctricos deben ser reparados por personal autorizado , tal como seria un ebctricista , descargas electricas y deben cumplir con las normas el6ctricas nacionabs y locales , El compresor tambien debe tener la clavija apropiada de tres terminabs para hacer tierra y contar con un suministro el6ctrico que sea del voltaje correcto y con un fusible de protecci6n adecuado , Nunca opere el compresor cerca de materiabs combustibles , gasolina ni vapores de Riesgo de solventes . Siesta rociando materiabs inflamabbs , coloque el compresor a una e × plosi6n y fuego distancia de cuando menos 6 metros del _ . rea de rociado . Nunca opere el compresor de aire en interiores o en lugares cerrados . Riesgo de estaHido Drene el compresor diariamente o despu6 . s de cada utilizaci6n . Si el tanque tiene una fuga , reemplace el compresor . Nunca utilice el compresor sise ha detectado una fuga , ! ni trate de modificar el tanque . Nunca modifique los ajustes de f6 , brica del compresor que controlan la presi6n del tanque y dem6 , s funciones . Especificaciones Bomba . . . . . . . . . . . . . . . . . . . . . . . . . . . . De impuisi6n Capacidad del tanque de aire . . . . . . . . . . . . . . . 45,4 litros directa , ] ubricada con aceite Presi6n de arranque . . . . . . . . . . . . . . . 655,0 KPa / 95 PSi Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . 1,0 HP ( Inducci6n ) Presi6n de parada . . . . . . . . . . . . . . . . 861,8 KPa / 125 PSi Diametro . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 mm PiescObicosperminute ( SCFM ) a 90LPPC . . . . . . . . . . . . . . . . . . . . . 2,4 Carrera . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 mm Capacidad del aceite . . . . . . . . . . . . . . . . 90 ml o 3 onzas , Voltaje monof _ . sico . . . . . . . . . . . . . . . . . . . . . . . . . 120 VAC Tipo de aceite . . . . . . . . . . . . . . . . . . SAE 30 - no detergente Capacidad minima del circuito . . . . . . . . . . . . . . . . . . . 15 A Glosario CFM : Pies cObicos por minuto , Presi6n de arranque : El compresor arranca automaticamente cuando la presidn baja a menos SCFM : Pies cObicos est _ , ndar por minuto ; unidad de del minimo prescrito , medici6n de suministro del aire , Presi6n de parada : El motor se para cuando el tanque alcance la presi6n maxima de aire , PSlG : Libras por pulgada cuadrada sobre la presi6n Certificaci6n de c6digo : Los productos que tienen atmosferica ; unidad de medici6n de presi6n , alguna o varias de las siguientes marcas han sido evaluados pot laboratorios de seguridad ASME : Sociedad estadounidense de ingenieros mecAnicos , independientes certificados per OSHA , y cumplen C6digo de California : La unidad puede cumplir con el con las normas de seguridad de Underwriters c6digo de California 462 ( I ) ( 2 ) / ( M ) ( 2 ) , Laboratories : UL , , ETL , CSA , Cicio de traba ] o Este compresor tiene un ciclo de trabajo de 50 % , Nunca opere el compresor per mas de 30 minutos cada hora , Ya que al hacerlo , podria dafiarlo , 12
Page: 15

Partes y caracteristicas Como referencia , vea Uasfiguras abajo . ManAmetro de presiAn deJ tanque Indica la presi6n de la reserva de aire del tanque . FHtro deJ aire Suministra aire limpio a la bomba . Siempre ManAmetro de presiAn de saHda debe conservarlo limpio . Reviselo diariamente o Undica Uapresi6n de saHda deUaire que entra antes de cada uso . en Uaherrambnta , UacuaUque es controUada per eI reguiador . Conector de acopJamiento rApido PermRe conectar y desconectar rApidamente la manguera deI aire . Regulador La presi6n del aire que sale del tanque es controlada per el regulador . Para aumentar la presi6n , Tap6n de gire la perilla en direcci6n de las Jtenado de manecillas ; para disminuirla , gire la aceite perilla en direcci6n contraria alas @ maneciiias . VAlvula de seguridad dei tanque Permite que el exceso de presi6n en Visor de el tanque escape hacia el medio aceite ambiente . Esta vAIvula s61o se abrirA cuando la presi6n en el tanque este por encima de la presi6n maxima nominal del modelo . Tubo de eaJida lnterruptor de presiAn Controla el suministro electrico en el motor y tambien los ajustes de presi6n de arranque y presi6n de parada . Este interrupter sirve como posici6n de autoencendido y apagado ( Auto - On / Oft ) de la unidad . VAJvula de aJivio de presi6n Esta valvula , que se encuentra en el costado del interruptor de presi6n , esta dise _ ada para liberar aire comprimido de manera automatica cuando el compresor llegue a la 13
Page: 16

Ensamblaje Antes de reaHzar cuaUqubr instaUaci6n y ensamMaje aU compresor de aire , se b debe apagar y desconectar deU Grounded generador , ademAs de purgar eUaire deUtanque y darb Ouh'et suficbnte tbmpo para enfriarse , Exbte eUrbsgo de que Uaspartes m6vHes , Uafuente eU6ctrica , eUaire comprimido Grounding Pin y Uassuperficies caHentes provoquen bsiones , EUenso ambb deUreguUador debe estar instaUado antes de usar eU compresor , Un ensamMaje inadecuado puede ser causa ebctricista o agente de servicio calificado si no de fugas y posibbmente de bsiones , Si no esta seguro entiende compbtamente estas instrucciones , o si de entender Uasinstrucciones de ensambUaje o tbne difio tiene dudas sobre la correcta puesta a tierra de la cultad para Ibvar a cabo el armado , por favor Ilame a su herramienta , departamento local de servicio , _ = nsamblaje 1 . Remueva e ! compresor de aire , manual , ensambbje del fiRro Una conexi6n a tierra inadecuada puede provocar una de aire y accesorios de la empaquetadura . descarga electrica , Si necesita reparar o cambiar el cable 2 , Remueva el tap6n de plAstico de la salida de aire o la clavija , no conecte el alambre de tierra a ninguna del compresor , ( ver abajo ) de las terminales planas , El alambre de tierra es el de 3 , Instalar el filtro dentro de la entrada de aire color verde , con o sin franjas amarillas . Si no entiende del compresor , ( ver abajo ) completamente las instrucciones de conexi6n a tierra , 4 , Remueva la tapa del tanque de aceite del carter o si tiene dudas sobre la correcta puesta a tierra de del motor y 116nelohasta Ibgar el punto rojo marcado la herramienta , hable con un electricista o agente de en el vidrio transparente , La capacidad de aceite es servicio calificado , No modifique la clavija que viene con 3oz ( ver abajo ) , Utilice SAEo30 sin detergente el equipo ; si no puede enchufarla en el tomacorriente , ( API CG / CD aceite para motores de gran capacidad ) , llame a un electricista calificado para que le instale el En case de fries extremes utilice aceite pesado SAEolO , tomacorriente adecuado , 5 , Coloque nuevamente la tapa del tanque de aceite , Este producto estA dise _ ado para trabajar en un circuito con un voltaje nominal de 120 voltios y esta equipado con un cable y clavija que permiten su conexi6n a un circuito electrico apropiado , Asegurese de que el producto este conectado a un tomacorriente con la misma configuraci6n Tiempo estimado de ensambtaje : Aproximadamente que la clavija , No se debe usar un adaptador con este 5 minutos equipo , Si se debe conectar el equipo a un circuito el6ctrico de diferente tipo , consiga la ayuda de personal Primer paso : Ubicacidn del compresor de aire calificado para realizar la reconexi6n , El compresor de aire siempre debe estar en un medio Cables de extensidn ambiente limpio , seco y bien ventilado , La unidad debe S61o utilice un cable de extensi6n de tres alambres con tener por Io menos 30 cm de espacio libre en cada lado , La toma del filtro de aire debe estar limpia y sin ningun una clavija con extensi6n a tierra de tres terminales que tipo de obstrucciones , Por favor revise diariamente el fib pueda enchufarse en un tomacorriente de tres orificios , tro de aire para comprobar que este limpio y en correcto Asegurese de que su cable de extensi6n este en buenas estado de funcionamiento , condiciones , Si utiliza un cable de extensi6n , compruebe que sea de la capacidad de corriente que requiere su Instrucciones de conexi6n a tierra equipo , Las extensiones no deben ser de mAs de 25 pies Este producto se debe conectar a tierra , En caso de ( 7,6 m ) de largo y deben tener cable de calibre 12 AWG , cortocircuito , la conexidn a tierra reduce el riesgo de Un cable mas delgado provocara una caida en el voltaje descargas el6 . ctricas al ofrecer una ruta de escape de linea , Io que provocaria una p6 . rdida de potencia y sobrecalentamiento , para la corriente el6ctrica , Este producto cuenta con un cable que tiene un alambre de tierra y una clavija con terminal de tierra ( ver la figura a continuacidn ) , La Procedimiento inicial de preparacidn clavija debe enchufarse en un tomacorriente instalado No se requiere un procedimiento inicial de preparaci6n , y puesto a tierra segun las normas locales , Habb con Este producto ha sido probado en la fAbrica para un asegurar su operaci6n y desempe _ o adecuados , 14
Page: 17

Procedimientos de operaci6n Procedimiento diario de arranque Enchufe el cable de corriente en un tomacorriente 1 . Ponga e [ [ nterruptor AutooOn / Often [ a pos [ c [ 6n de 6 . apagado ( Oft ) . apropiado . 2 . Vedfique que e [ compresor de [ a [ re , [ a manguera de 7 . Mueva el interruptor AutooOn / Offa la posici6n de a [ re y todos los accesodos / herram [ entas utH [ zados , no encendido ( AutooOn ) ; el compresor debera arrancar , tengan da _ os n [ obstrucc [ 6n . S [ a [ gunas de [ as p [ ezas acumu [ ando [ a presi6n de [ aire en el tanque hasta descr [ tas requ [ eren raparac [ 6n / reemp [ azo , flame a su flegar a [ a presi6n de apagado , momento en el cua [ se t [ enda autor [ zada local de serv [ c [ o , antes de usar e [ apagar # , de manera automa . tica . compresor . 8 . Ajuste el regu [ ador a [ a presi6n de aire recomendada 3 . C [ erre [ a vbJvu [ a de drenaje . ( PSI ) para su apficaci6n , cerciora . ndose de que este 4 . Revise e [ n [ ve [ de ace [ te de [ a bomba . dentro de [ as normas de seguridad para flevar a cabo 5 . Enchufe [ a manguera de [ a [ re dentro de [ conector de [ a tarea . Para [ as herramientas neum6 . ticas , el manual de [ fabricante debe tener recomendaciones sobre su acop [ amiento rApido de [ a unidad de [ regu [ ador , insertando [ a c [ avija de conexi6n rApida en [ a presi6n de operaci6n ( PSI ) . manguera de [ aire , dentro de [ conector de 9 . Ahora el compresor de [ aire est _ fisto para set usado . acop [ amiento r # . pido . El coflarin de [ conector de Los siguientes accesorios de inflado y de fimpieza , los acop [ amiento r # . pido sa [ tara hacia ade [ ante , sujetando cua [ es vienen con esta unidad , s6 [ o se deben operar a la davija y hara una junta entre el conector y la davija . una presi6n maxima de 90 PSI : sop [ ete , boquifla c6nica Para desconectar [ a manguera de [ aire , empuje hacia de caucho , agujas para inflar , adaptador y adaptador de atr # . s el coflarin de [ conector de acop [ amiento r # . pido . sop [ ete . Procedimiento diario de apagado 1 . Ponga el interrupter en [ a posici6n de apagado ( Oft ) . 2 . Desconecte el cable de [ tomacorriente . A [ drenar el tanque uti [ ice protecci6n para oidos y ojos . 3 . Ponga en cero el regu [ ador de presi6n de sa [ ida . Drene el tanque en un [ ugar apropiado ; en [ a mayoria de 4 . Desconecte [ as herramientas y los accesorios . [ as ocasiones a [ drenar sa [ dr # , condensaci6n . Siempre use protecci6n para los oidos y los ojos a [ drenar el tanque . Drene el tanque en un [ ugar adecuado ; en casi todos los cases habr # , presencia de condensaci6n en el drenaje . Si no drena el tanque a [ a [ macenado , en su interior 5 . Abra [ a vA [ vu [ a de drenaje permitiendo que escape el quedar _ , agua que Io corroer # , y debifitara , , Io cual puede aire de [ tanque . Cuando haya safido de [ tanque todo el provocar su ruptura . Para evitar [ esiones graves , drene el aire , cierre [ a v6Jvu [ a de drenaje para evitar que entre suciedad . tanque diariamente o despues de cada uso . 15
Page: 18

Mantenimiento NOTA : CuaHquierprocedimiento de servicio que no este Asuntos para verificar / Antes de cada uso cubierto en eHprograma de mantenimiento que sigue carnbiar o diariamente deber _ ser efectuado eHpersonaHde servicio caHficado , Revisar la vb . lvulade seguridad del X tanque Antes de dar mantenimiento aHequipo , se debe apagar Revisar visuaHmente eHaspecto X generaH de Haunidad y desconectar dell tomacorriente , as [ como purgar eHaire dell tanque y permitir que Haunidad se enfrie , Revisar eHfiHtrode aire X Drenar eHtanque X A fin de asegurar una operaci6n eficiente y una Harga Verificar que eHcabHe eHectrico X vida dell compresor , debe seguir un programa de no este daSado mantenimiento de rutina , EHsiguiente programa de Cambiar eHaceite Despues de las primeras mantenimiento esta enfocado aHconsumidor cuyo 50 horas compresor es usado en un medio ambiente normaHy diariamente , Verificar eHniveHdell aceite Despues de cada 100 horas Para aHmacenar eHcompresor , asegurese de hacer Hesiguiente : 1 , Apague Haunidad y desconecte eHcame eHectrico dell 4 , Abra Havb , HvuHade drenaje para drenar eHaire dell tomacorriente , tanque , 2 , Quite dell compresor Hasmangueras , accesorios y 5 , Cierre Hav6 , HvuHade drenaje , herramientas de aire , 6 , Guarde eHcompresor en un HugarHimpioy seco , 3 , LHevea cabo eHprograma de mantenimiento de rutina , NOTA 16
Page: 19

Oiagn6stico y correcci6n de fallas Antes de Ilevara cabo cualquier correcci6n de probbmas o tarea , el compresor de aire se debe apagar y desconectar deI tomacorriente , Purgue el aire del tanque y permita que la unidad se enfr [ e . Las partes en movimiento , las fuentes electricas , el aire comprimido y las superficies calbntes pueden provocar Iesiones . PROBLEIVlA POSIBLE CORRECCI6N Fuga de aire en [ a va . [ vu [ a de Una v _ . ivula de retenci6n defectuosa provoca una fuga de aire constante en [ a retenci6n o en Uav _ JvuUade v6JvuUade aHvio cuando est6 . apagado eUcompresor tenbndo presi6n de aire , aHvio , Drene eUtanque y quite y Hmpb o cambb UavaUvuUade retenci6n , Fugas de aire entre Uacabeza Compruebe eUaprbte de bs pernos de la cabeza , Si continua la fuga , Ilame a un y el cilindro , tecnico de servicio , Fuga de aire en la valvula Opere manualmente la valvula de seguridad tirando del anillo , Si el tanque continua de seguridad , teniendo una fuga estando la v6Jvula en posici6n cerrada , esta deber _ ser cambiada , La presi6n indicada en el Si al usar un accesorio hay una ca [ da excesiva de presi6n , cambie el regulador , man6metro de presi6n regulada cae al usar un accesorio , Ajuste la presi6n regulada bajo condiciones de fiujo ( mientras se utiliza un accesorio ) , Es normal que el man6metro indique una caida de presi6n minima al comenzar a utilizar la herramienta , Presi6n excesiva Apague el interruptor de encendido , Si la unidad no se apaga , descon6 . ctela del en el tanque , tomacorriente y comuniquese con un t6 . cnico de servicio , El motor no arranca , Compruebe que el cable de corriente este enchufado y que el interruptor este encendido , Compruebe que el fusible de la caja de circuitos sea de la capacidad adecuada , Si se ha disparado , restablezcalo y vuelva a arrancar la unidad , Si el fusible se dispara con frecuencia llame a un tecnico de servicio , Humedad excesiva en el Saque el agua del tanque drenandolo despues de cada vez que se use , En los aire de salida , medios ambientes de alta humedad habra , un exceso de condensaci6n ; instale filtros de agua en su linea de aire , La condensaci6n no es provocada pot una falla en el compresor , Compruebe que la salida de aire del compresor sea mayor que el consumo de aire de su herramienta , Fugas de aire en el cuerpo Nunca taladre , suelde o modifique de ninguna manera el tanque , pues se o la soldadura del tanque , debilitara . , El tanque podria romperse o explotar , El tanque no puede set reparado , Ya no utilice el compresor de aire , 17
Page: 20

Your Home For repair = in your home = of all major brand appliances , lawn and garden equipment , or heating and cooling systems , no matter who made it , no matter who sold it ! For the repWacement parts , accessories and owner's manuals that you need to do = it = yourself . For Sears professional installation of home appliances and items like garage door openers and water heaters . ( t ° 800 - 469 - 46 ¢ 3 ) Call anytime , day or night ( U . S . A . and Canada ) www . sears . com www . sears . ca Our Home For repair of carry - in items like vacuums , lawn equ ; pment , and electronbs , calWor go on - line for the location of your nearest Sears Parts & Repair Center . 1o800o488ol 222 Call anytime , day or night ( U . S . A . only ) www . sears . com To purchase a protection agreement ( U . S . A . ) or maintenance agreement ( Canada ) on a product serviced by Sears : 1 ° 800 - 827 ° 6655 ( U . S . A . ) 1 - 800 - 361 ° 6665 ( Canada } Au Canada pour service en frangais : Para pedir servbio de reparaci6n a domicilio , y para ordenar piezas : 1 - 800 = LE - FOYER Mc ( 1 - 800 - 553 - 6937 ) ( 1 ° 888 ° 784 ° 6427 ) www . sears . ca TM SM @ Registered Trademark / Trademark / Service Mark of Sears , Roebuck and Co . T _ ' 4 M @ Marca Registrada / Marca de Fabrica / s Marca de Servicio de Sears , Roebuck and Co . MD MCMarque de commerce / Marque d6pos6e de Sears , Roebuck and Co . _ : _ Sears Brands , LLC