Page: 1 TEC / THC FEATURES • Super efficient , slim design . • Cooling efficiencies as high as 11.0 EER . • Contoured discharge design blends with any decor . • Large well - spaced switch buttons . • Easy to read and understand controls . • Control knob and buttons not removable by the user . • Flush floor mount capability with recessed front return . • Lockdown front panel . • Even - temp heat anticipator temperature control for maximum comfort . • Thermostat limiter device . • Quiet , efficient rotary compressors mounted on vibra - tion isolators , with internal high temperature overload protection . • Indoor and outdoor tangential blower wheels provide even air distribution . • Concealed vent control and fan cycle switch . • Emergency heat compressor override switch on all heat pumps . • Up to 420 CFM indoorsfor maximum air throw . • Two cooling and two heating fan speeds . • Slide - out top mount filter for easy cleaning . • High efficiency , PSC fan motor with permanently lubricated bearings , built - in thermal protection . • Isolatedcompressorcompartment . • Overcurrent protection ( fuse ) standard on 265 volt units . • Efficient nichrome wire heater design for long life . • Draw - through condenser and evaporator coils for easier cleaning . • Completelineofaccessories . Options available : • Wall mounted remote thermostat • Central desk control with low temperature protection . • Seacoast protection . @ @ ® c ® It mattem ! i " af . , T _ j " ai ; I'Jlr , t _ ] _ Page: 2 MODEL TECO7K TECO7R TEC09K TECO9R TECI2K rEC12R TECI5K TECI5R VOLTAGE 11Ph - 60 Hz I 2301208 265 230 / 208 265 230 / 208 285 2301208 285 COOLING CAPACITY CBTUh ) 670016500 6700 920019100 9200 11700111500 11700 14400 / 14200 14400 POWER ( WATTS ) 670 / 650 670 815 / 795 815 1170 / 1150 1195 1565 / 1540 1565 CURRENT CAMPS ) 3.0 / 3.2 2.6 3.8 / 4.0 3.7 5.1 / 5.6 4.6 7.3 / 7.9 6.0 EER 10.0 / 10.0 10.0 11.0 / 11.0 11.0 10.0 / 10.0 9.8 9.2 / 9.2 9.2 DEHUMIDIFICATION RATE CPTS / Hr ) 1.6 1.6 2.2 2.2 3.0 3.0 4.0 4.0 SENSIBLE HEAT RATIO . 80 . 80 . 77 . 77 . 76 . 76 . 72 . 72 LOCKED ROTOR AMPS CCompressor ) 18.0 12.0 23.0 16.0 26.3 28.0 38.0 32.0 INDOOR CFM ( DRY COIL - HI ) 250 / 230 250 310 / 290 310 400 / 380 400 420 / 400 420 VENT CFM fill ) * 70 70 70 70 80 80 80 80 N ET WEtG HT ( AP PROX , - LBS ) 104 104 111 111 117 117 117 117 SHIPPING WEIGHT ( APPROX . - LBS ) 122 122 129 129 135 135 135 135 NOTE : Cooling capacity rated in accordance with ARI standard 310 at conditions of 80OF DB / 67 ° F WB outdoor . * An approximate number based on laboratory tests . Actual performance may vary based on actual application . MODEL THC07K THCO7R THC09K THC09R THCI2K THCI2R THCI5K rHCISR VOLTAGE f 1 Ph - 60 Hz ) 230 / 208 265 230 / 208 265 2301208 265 2301208 285 COOLING DATA COOLING CAPACITY CBTUh ) 670016500 6700 920019100 9200 11700111500 11700 14300 / 14100 14300 POWER CWATTS ) 670 / 650 670 815 / 795 815 1170 / 1150 1195 155511530 1555 CURRENT CAMPS ) 3.0 / 3.2 2.6 3.8 / 4.0 3.7 5.1 / 5.6 4.6 7.3 / 7.9 6.0 EER 10.0 / 10.0 10.0 11.0 / 11.0 11.0 10.0 / 10.0 9.8 9.2 / 9.2 9.2 DEHUMIDIFICATION RATE ( PTS / Hr ) 1.6 1.6 2.2 2.2 3.0 3.0 4.0 4.0 SENSIBLE HEAT RATIO . 80 . 80 . 77 . 77 . 76 . 76 . 72 . 72 LOCKED ROTOR AMPS CCompressor ) 18.0 12.0 23.0 16.0 26.3 28.0 38.0 32.0 HEA'RNG DATA ( REVERSING CYCLE ) HEATING CAPACITY ( BTUh ) 8300 / 6100 6300 8000 / 7800 8000 11300111100 11300 13300113100 13300 POWER ( WATTS ) 6151595 615 735 / 715 735 103511015 1035 1260 / 1240 1260 CURRENT CAMPS ) 2.7 / 2.9 2.4 3.3 / 3.6 3.6 4.6 / 5.0 4.0 5.5 / 6.0 4.9 COP 3.0 / 3.0 3.0 3.2 / 3.2 3.2 3.2 / 3.2 3.2 3.1 / 3.1 3.1 INDOOR CFM CDRY COIL - HI ) 2501230 250 3101290 310 4001380 400 420 / 400 420 VENT CFM CHI ) * 70 70 70 70 80 80 80 80 NET WEIGHT ( APPROX , - LBS ) 106 106 113 113 119 119 119 119 SHIPPING WEIGHT / APPROX . - LBS ! 124 124 131 131 137 137 137 137 NOTE : Cooling capacity rated in accordance with ARI Standard 380 at conditions of 80 ° F DB / 67 ° F WB indoor and 95 ° F DB / 75 ° F WB outdoor . Heating capacity rated in accordance with ARI Standard 380 at conditions of 70 ° F DB / 60 ° P WB indoor and 47 ° F DB / 43 ° F WB outdoor . * An approximate number based on laboratory tests . Actual performance may vary based on actual application . | = IHII | : I _ = : _ Il = = k " il _ € 1lll1l 1 € [ 1q | " t [ O , ] ll " I _ _ , ' 111 _ [ L " II _ HEATING HEATING HEATING MINIMUM BRANCH HEATER CAPACITY POWER CURRENT CIRCUIT CIRCUIT MODEL NO . VOLTAGE WATTS AMPACITY ( BTUh ) ( WATTS ) ( AMPS ) FUSE ( AMPS ) 14.1 230 / 208 2500 / 2050 8500 / 7000 260012150 11.4 / 10.4 15 TE / THC07K 230 / 208 3400 / 2780 1160019500 3500 / 2880 15.3 / 13.9 19.0 20 285 2500 8500 25 £ 0 9.8 12.2 15 TE _ HC07R 285 3400 11600 34 £ 0 13.2 16.4 20 230 / 208 2500 / 2050 8500 / 7000 2710 / 2260 11.5 / 10.5 14.3 15 TE _ HC09K 14.5 / 14.0 230 / 208 3400 / 2780 1160019500 3610 / 2990 19.1 20 TE _ HC12K 27.8 230 / 208 500014090 17000 / 13900 5210 / 4300 22.3 / 20.3 3O 285 2500 8500 2710 10.0 12.3 15 TE _ HC09R 285 3400 11600 3610 13.4 16.6 2O TE _ HC12R 285 5000 17000 5210 19.5 24.2 3O 14.4 230 / 208 2500 / 2050 8500 / 7000 2740 / 2290 11.7 / 10.7 15 TE _ HC15K 230 / 208 3400 / 2780 1160019500 364013020 15.6 / 14.2 19.3 20 230 / 208 500014090 17000 / 13900 5240 / 4330 22.5 / 20.5 27.9 3O 285 2500 8500 2740 10.1 12.5 15 285 3400 11600 3640 13.5 16.7 2O TE _ HC15R 285 5000 17000 5240 19.6 24.3 3O NOTE : Proper sizing of PTAC / PTHP equipment is critical to its performance . Please consult your specifying engineer for recommendations . SPECIFICATION SUBJECT TO CHANGE WITHOUT NOTICE 2 Page: 3 Ill I ; _ lll II = = I1Ivile ] Ilj _ 1li _ Illl Ivil7 , MODEL NUMBER T H C K ST B 25 SERIES ENGINEERING CODE T = T Series A = Accessory ST = Standard Model E = Cooling with or without Electric Heat RT = Remote Thermostat DC = Central Desk Control H = Heat Pump SP = Seacoast Protection DESIGN SERIES NOMINAL HEATER SIZE NOMINAL CAPACITY ( 230V or 265V ) 07 = 6,500 - - 7,200 BTUh 00 = No heater 09 = 8,500 - - 9,200 BTUh 25 = 2.5 KW 12 = 11,500 - - 12,000 BTUh 34 = 3.4 KW 15 = 14,000 - - 15,000 BTUh 50 = 5.0 KW VOLTAGE K = 230 / 208V - 1 Ph - 60 Hz R = 265V - 1 Ph - 60 Hz NOTE : Proper sizing of PTAC / PTHP equipment is critical to its performance . Please consult your specifying engineer for recommendations . OUTDOOR DRY BULB TEMPERATURE ( DEGREES F . AT 40 % R . H . ) MODEL 75 ` = 85 ° 95 ° 105 ° 115 ° NUMBER INDOOR WET BULB TEMPERATURE DEGREES F . AT 80 ° F D . B . ) 72 67 62 72 67 62 72 67 62 72 67 62 72 67 62 BTUh 7980 7620 7170 7680 7220 6730 7310 6700 6170 6860 5980 5600 6030 5060 4670 WATTS 560 555 550 610 605 600 675 670 665 730 725 720 785 780 775 TE / THC07 AMPS * 2.5 2.5 2.5 2.7 2.7 2.7 3.0 3.0 3.0 3.2 3.2 3.2 3.5 3.5 3.5 SHR * * . 52 . 71 . 96 . 53 . 76 . 97 . 54 . 80 . 96 . 55 . 87 . 97 . 60 . 92 . 94 BTUh 10870 10200 9440 1044C 9700 8940 9950 9200 8200 9150 8250 7450 8200 7200 6380 TE / THC09 WATTS 700 690 685 760 755 750 825 815 810 890 880 865 955 950 945 AMPS * 3.6 3.6 3.6 3.7 3.7 3.7 3.8 3.8 3.8 3.9 3.9 3.9 4.3 4.3 4.3 HR * * . 54 . 72 . 98 . 55 . 74 . 95 . 56 . 77 . 97 . 57 . 82 . 98 . 58 . 90 . 98 BTUh 13540 13110 12200 1265C 1199C 11200 1228G 11700 10080 1150C 10370 8930 10090 8920 8060 TE / THC1214 WATTS 930 960 985 1015 1040 1065 1165 1170 1175 1250 1255 1260 1370 1385 1395 ( 230 / 208V ) AMPS 4.3 4.3 4.3 4.5 4.5 4.5 5.1 5.1 5.1 5.5 5.5 5.5 6.0 6.0 6.0 SHR * * . 53 . 72 . 96 . 53 . 73 . 99 . 54 . 76 . 97 . 57 . 79 . 98 . 58 . 86 . 98 BTUh 13540 13110 12200 1265C 1199C 11200 1228G 11700 10080 1150C 10370 8930 10090 8920 8060 TE / THCI2R WATTS 955 980 1005 1040 1060 1080 1190 1195 1200 1275 1280 1290 1400 1415 1425 ( 265V ) AMPS 3.9 3.9 3.9 4.1 4.1 4.1 4.6 4.6 4.6 5.0 5.0 5.0 5.4 5.4 5.4 SHR * * . 53 . 72 . 96 . 53 . 73 . 99 . 54 . 76 . 97 . 57 . 79 . 98 . 58 . 86 . 98 BTUh 17010 16330 14810 1633C 1535C 13820 15660 14400 12540 1463C 13060 11060 1336G 11500 9490 TEC15 WATTS 1280 1310 1330 1390 1410 1440 1560 1565 1570 1700 1700 1715 1870 1860 1885 AMPS * 5.9 6.0 6.2 6.5 6.6 6.7 7.2 7.3 7.4 7.9 7.9 8.0 8.6 8.6 8.7 SHR * * . 51 . 69 . 93 . 53 . 71 . 95 . 52 . 72 . 99 . 52 . 75 . 99 . 54 . 79 . 99 BTUh 16890 16220 14710 1622C 1524C 13720 1555G 14300 12450 1453C 12970 10980 1327G 11420 9420 THC15 WATTS 1270 1305 1320 1380 1405 1430 1550 1555 1560 1690 1690 1705 1860 1850 1875 AMPS * 5.9 6.0 6.2 6.5 6.6 6.7 7.2 7.3 7.4 7.9 7.9 8.0 8.6 8.6 8.7 SHR * * . 51 . 69 . 93 . 53 . 71 . 95 . 52 . 72 . 99 . 52 . 75 . 99 . 54 . 79 . 99 * 230V only ; use ratio from rating condition for other voltages . * * Sensible Heat Ratio SPECIFICATION SUBJECT TO CHANGE WITHOUT NOTICE 3 Page: 4 OUTDOOR DRY BULB TEMPERATURE DEGREES F ) * * Model Number 37 42 47 52 57 BTUh 5250 5540 6300 6900 7620 THC07 WATTS 580 590 615 625 660 AMPS * 2.6 2.7 2.7 2.8 2.9 BTUh 5930 6320 8000 8540 9130 THC09 WATTS 660 670 735 740 750 AMPS * 3.2 3.2 3.3 3.3 3.4 BTUh 8160 9010 11300 11910 12920 THC12 WATTS 905 940 1035 1065 1100 AMPS * 4.1 4.2 4.6 4.8 5.0 BTUh 10530 10850 13300 14550 15940 THC15 WATTS 1160 1175 1260 1335 1395 AMPS * 5.0 5.1 5.5 5.8 6.0 * 230V only ; use ratio from rating condition for other voltages . RATING * * Indoor temperature at 70 ° F D . B . POINT Entering Indool Correction Entering Indoor Wet Bulb F ° D . B . F ° 61 Factor 59 63 65 67 69 71 70 . 90 . 93 . 96 . 99 1.02 Total Cap . Mult . . 84 . 83 . 91 . 77 . 70 Sens Cap . Mult . 75 . 89 . 92 . 95 . 98 1.01 1.04 i Total Cap . Mult . 1.04 1.03 1.00 . 95 . 88 . 78 i Sens Cap . Mult . 80 . 88 . 91 . 94 . 97 1.00 1.03 1.06 Total Cap . Mult . 1.14 1.15 1.16 1.08 1.00 . 89 . 73 Sens Cap . Mult . 85 . 90 . 93 . 96 . 99 1.02 1.05 Total Cap . Mult . 1.22 1.18 1.20 1.11 . 98 . 81 Sens Cap . Mult . Bold Type = Approximately 50 % RH Depth 18 1 / 2 in , ( 470 ram ) ( 1067 ram ) Outdoor Wall Sleeve A 42 _ ' i \ TOP VIEW ( 292 ram ) 181j2 " ( 470 ram ) 265V I I I CZZ Conduit Attachment0 ) Front Panel ( Note 1 DIscharge Louver / _ ( J [ ZI ' . - L4 I I ÷ 7 " 4 ( 114mm ) SPECIFICATION SUBJECT TO CHANGE WITHOUT NOTICE 4 Page: 5 = 1 . The recommended rough - in wall opening is 16 - 1 / 4 " 8 . The discharge louvers are shipped from the factory in ( 412 mm ) high by 42 - 1 / 4 " ( 1073 mm ) wide . a position to provide the maximum air circulation . The louvers can be installer / owner adjusted to 2 . The wall sleeve must be installed level side to side provide air discharge 10 ° from the vertical . and front to back , and extended outdoors at least 1 / 4 " ( 6 mm ) for proper caulking and sealing . No 9 . The return air louver section is easily removed for fasteners are to be installed in the bottom of the access to the fan cycle switch , emergency heat sleeve , switch and vent lever . The louver can be secured to the front panel , thereby restricting access , by install - 3 . The unit may be mounted flush with the floor . Any ing two field - supplied screws . carpet and pad height should be considered to insure proper air return . 10 . On 265 V units , 1 / 2 " ( 13 mm ) conduit ( factory accessory or field - supplied ) attaches directly to the 4 . It is recommended that walls less than 4 " ( 102 mm ) unit control box , with a 90 ° connector , to form a thick use a subbase or other means of sleeve permanent connection . The conduit is required to support , meet NEC Codes . 5 . Refer to the dimensional drawings for wall sleeve 11 . All 265 volt units include time - delay cartridge fuses for installation when a subbase or lateral duct is used . overcurrent protection . 6 . The front panel is shipped with the chassis , and 12 . A freeze - up sensor on the outdoor coil of heat pump secures with two screws ( provided ) . models automatically switches the unit to electric heat 7 . For total elimination of cooling or heat pump mode . The actual heat pump switch - over point is condensate , a condensate drain kit must be used dependent on indoor and outdoor air flow , tempera - in conjunction with an internal condensate tures , humidity and unit capacity . drainage system 13 . Condensate is pumped to the condenser coil where coil heat and air movement evaporate the majority of the moisture . Any excess is drained off . The following standard options are available on a build - to - provide heat to its environment , preventing cold weather order basis and are not field - supplied . All of the 230 / 208 damage to facilities , contents and plumbing , included with volt models are cord - connected . The 265 volt models this PTAC option is a normally closed relay which can be wired , via a unit - mounted terminal board , to a remote require conduit to form a permanent connection . This conduit can be field - supplied or ordered as a separate central station , such as the front desk of a hotel . accessory ( refer to hard wire kits on the accessory list ) . Refer to local codes for complete electrical requirements . Power at the PTAC controls can be interrupted from the central desk with a field - supplied 24 volt connection . Low NOTE : ONLY ONE OPTION PER UNIT CAN BE USED . indoor temperature protection is standard with this option . In the " unoccupied " mode , power to the PTAC controls is Remote Thermostat " RT " interrupted by the central desk control . Should the room temperature fall to 43 ° F , the PTAC will automatically This option is to be used when the specification calls for override the central desk control and energize the fan remote , wall - mounted , temperature sensing and control . motor and electric heater to warm the space to approxi - The PTAC unit includes the necessary transformer , mately 58 ° F , thus preventing possible freezing and relays , and low voltage terminal board for proper interface bursting of water pipes . The PTAC then returns to the to the following 24 volt thermostat and thermostat sub - " unoccupied " mode . Full user control is restored to the base combination : PTAC once the central desk deactivates the 24 volt power supply ( " occupied " mode ) . TYPE THERMOSTAT + THERMOSTATSUBBASE Manual TAT99TM TAT99SM Seacoast Protection " SP " Changeover ( T87F2873 ) ( Q53931006 ) For additional protection , when a PTAC unit is to be Central Desk Control " DC " installed in a coastal or corrosive environment the " SP " option is strongly recommended . In addition to the unit's Central Desk Control is available on all models , and standard features , the entire outdoor coil is submerged in provides extra protection in areas which are not consis - a specially formulated enamel coating , then oven cured for tently occupied such as hotels and motels . When the a tough , corrosion - resistant finish . room is unoccupied , the central desk can turn off heating and air conditioning service . While in this mode , the Please contact your sales representative regarding use of PTAC would be able to sense low temperatures , and the seacoast protection option and seacoast protection related warranty coverage . 5 Page: 6 Air flow shall be directed into the room by a polycarbonate discharge grille that is factory preset to provide maximum NAMEPLATE WALL RECEPTACLE RECEPTACLE air circulation into the room . The grille shall be owner RATING NUMBER CONFIGURATION adjustable to 10 degrees off the vertical . A fine mesh screen shall be used in the ventilation air stream . MAX UNIT VOLTS AMPS * Controls 230 / 208 12.0 NEMA 6 - 15R Covered controls on the top - front of the unit shall include a push button mode selector switch , rotary thermostat control and a rocker switch to select the fan speed . 230 / 208 16.0 NEMA 6 - 20R The thermostat knob and the push buttons shall not be removable by the user . The buttons on the switch shall be 230 / 208 24.0 NEMA 6 - 30R sized and spaced to prevent the possibility of depressing two buttons at one time . All 265 volt units must be permanently connected . Conduit The control panel shall be easy to read and understand assembly , factory or field - supplied , can be wired directly to with the markings for the mode selection no smaller than the unit . 14 point type . International symbols shall be used . A room temperature limiting device , inaccessible to the user , shall be owner adjustable . * This is normally the electric heating amps , except for cooling only models . Restricted to the user , but accessible without removing the front panel , shall be the fan cycle switch , the vent control , and the emergency heat compressor override switch ( on = II " . I heat pump models ) . The fan cycle switch shall select continuous or intermittent fan operation , whereby the The supplier will furnish packaged terminal air condition - blowers cycle with the compressor or heater . ers or heat pumps in the capacities shown on the specifi - cations . The minimum efficiency levels shall be no less General Construction than - EER . The wall sleeve shall be constructed of 18 ga . G90 zinc - Units shall be certified in accordance with ARI Standard coated steel . It shall be prepared by a process where it is 310 for air conditioners and ARI Standard 380 for heat zinc phosphate pretreated and sealed with a chromate pumps . All units shall be UL listed . rinse , then electrostatically coated with a polyester finish , and oven cured for durability . It shall be insulated for Basic unit dimensions shall not exceed 42 in wide and thermal efficiency . The sleeve shall be shipped with a 16 in . high . Overall depth of the unit from the rear of the protective weatherboard and a structural center support . wall sleeve to the front of the front panel shall not exceed 18 - 1 / 2 in . Overall depths of the unit from the rear of the The outdoor grille shall be shipped separately The grille wall sleeve to the front of the front panel shall not exceed shall be fabricated from stamped or extruded anodized 20 - 1 / 2 in . ( NOTE : Deep wall sleeve extension may add aluminum . Louvers shall be in a horizontal pattern . up to 4 in . additional depth on all models . ) The front panel shall lock to the chassis , thereby providing Refrigeration System a tamper - resistant design . The front panel shall have a contoured air discharge with no sharp corners . The air The refrigeration system shall consist of a hermetically filter shall be a slide - out , top - mount design and removable sealed rotary compressor that is externally mounted on without opening or removing the front panel . vibration isolators , condenser and evaporator coils constructed of copper tubes and aluminum plate fins and The unit shall be capable of mounting flush with the carpet capillaries as refrigerant expansion devices . and shall possess a recessed , front return to provide toe - space clearance . The coils shall be of a draw - through design to facilitate cleaning . The compressor and fan motor shall be located All 265 volt units shall possess an integral over - current ina separate compartment that is isolated from conden - time - delay protective device . sate splatter . Limited Warranty Air Handling Section First Year : Parts and labor on the entire unit Second The indoor and outdoor fans shall consist of tangential through Fifth year : Parts and labor on the sealed blower wheels driven by one permanently lubricated split refrigeration system and Flex Drive _ systems . See the capacitor motor . warranty document for complete details . SPECIFICATION SUBJECT TO CHANGE WITHOUT NOTICE 6 Page: 7 ITEM DESCRIPTION MODEL NO . G - 90 zinc - coated steel is prepared in an eleven step process , then TAX99WB electrostatically coated with a polyester finish and cured in an oven for WALL SLEEVE exceptional durability . The wall sleeve is insulated for thermal effi - ciency . A 4 in deep , anodized aluminum extension that attaches to the rear of DEEP WALL SLEEVE the wall sleeve when the wall is greater than 11 in . thick ( 9 - 1 / 2 in . TAX04WE EXTENSION when a subbase is used , 10 in . when a lateral duct is used ) . Standard , stamped , aluminum - anodized to resist chalking and oxida - TAX99GA tion . Architectural grilles that consist of heavy gauge 6063 - T5 aluminum OUTDOOR LOUVERS alloy : - Clear extruded aluminum . TAXAA42 - Dark bronze acrylic enamel . TAXDB42 Attaches to the bottom of the wall sleeve for internal draining of con - CONDENSATE DRAIN KIT densate or to the rear wall sleeve flange for external draining . TAX99DR10 Packed in quantities of ten . CONTROL DOOR LOCK Lock , with 2 keys , installs quickly to restrict access to unit controls . TAX99DL Provides unit support for walls less than 4 in . thick . Includes leveling DECORATIVE SUBBASE legs , side filler panels and mounting bracket for accessory electrical TAX99SB receptacle . Accepts circuit breaker , power disconnect switch , conduit kit or electrical receptacle . Air baffle that quickly attaches to the condenser coil to provide proper CONDENSER BAFFLE KIT air separation when the unit is installed in one of the following sleeves : TAX99BK1 General Electric ( metal or plastic ) , Carrier ( metal or plastic ) , Amana / Trane , or McQuay N - series . POWER DISCONNECT A two - pole switch that easily installs in the subbase of 230 / 208 V or TAX99DS SWITCH 265 V units . ( TAX99SB subbase required . ) Hard wire conduit kit with junction box for 265 V unit ( subbase not CONDUIT KIT WITH required ) . TAX99CJ JUNCTION BOX Kit includes a means of quick disconnect for easy removal of the chassis . Honeywell 24 V wall mounted thermostat ( requires the appropriate THERMOSTAT Thermostat Subbase below ) : TAT99TM - Manual changeover ( T87F2873 ) THERMOSTATSUBBASE Honeywell 24 Vsubbase . TAT99SM - Manual changeover ( Q539J1006 ) Attaches to the PTAC / PTHP unit and provides a transition to direct up LATERAL DUCT ADAPTER to 35 % of the total CFM to a secondary room either left or right of the TAX99DA ( Requires Lateral Duct unit . Kit includes duct plenum , with discharge grille and internal baffle , Extension TAX99DE ) adapter , end cap and secondary room outlet grille with 2 - way deflec - tion . A three foot insulated plenum that attaches to the left or right side of LATERAL DUCT the duct adapter . The extension can be cut to length by the installer . TAX99DE EXTENSION Maximum allowable straight extension is fifteen feet . 7 Page: 8 WALLMASTER ® PACKAGED TERMINAL AIR CONDITIONERS AND HEAT PUMPS SAVE THIS CERTIFICATE . It gives you specific legal rights , and you may also have other rights which may vary from state to state and province to province . In the event your unit needs servicing , contact your nearest authorized service center . When requesting service , please have the model and serial number from your unit readily available . If you do not know the nearest service center , ask the company that installed your unit or contact us - see address and telephone number below . Fill in the installation date , model and serial number of the unit in the space provided below and retain this warranty for your files . Unless specified otherwise herein , the following applies : PACKAGED TERMINAL AIR CONDITIONERS AND HEAT PUMPS LIMITED WARRANTY - - FIRST YEAR ( Eighteen ( 18 ) months from the original date of purchase or twelve ( 12 ) months from Installation ) . Any defect in the unit'smaterials or workmanshipwillbe repaired or replaced free of charge by our authorized service center during normal working hours ; and LIMITED WARRANTY - - SECOND THROUGH FIFTH YEAR ( Sixty - six ( 66 ) months from the date of purchase or sixty ( 60 ) months from the date of installation , whichever comes first ) ON THE SEALED REFRIGERATION SYSTEM AND THE FLEX - DRIVE ® SYSTEM . Any partof the sealed refrigeration system , for theT Series , and the Flex - Drive @ System that is defective in material orworkmanshipwillbe repaired or replaced free of charge by our authorized service center during normal working hours . The sealed refrigeration system consists of the compressor , metering device , evaporator , condenser , reversing valve , check valve , and inter - connecting tubing . The Flex - Drive ® System consists of the polyurethane belt and the blower pulleys . These warranties apply only while the unit remains at the original site and only to units installed inside the continental United States , Alaska , Hawaii , Puerto Rico and Canada . The warranty applies only if the unit is installed and operated in accordance with the printed instructions and in compliance with applicable local installation and building codes , and good trade practices . For International Warranty information , contact the Friedrich Air Conditioning Company - International Division . Reasonable proof must be presented to establish the original purchase date , otherwise the beginning date of this certificate willbe considered to be our shipment date plus sixty days . Replacement parts can be new or remanufactured . Replacement parts and labor are only warranted for any unused portion of the unit's warranty . We will not be responsible for and the user will pay for : 1 . Service calls to : ( a ) instruct on unit operation , ( b ) replace house fuses or correcthouse wiring , ( c ) clean or replace air filters ( d ) remove the unit from inaccessible locations , and / or ( e ) correctimproper installations . 2 . Parts or labor provided by anyone other than an authorized service center . 3 . Damages caused by : ( a ) accident , abuse , negligence , misuse , riot , fire , flood , or Acts of God , ( b ) operating the unit where there is a corrosive atmosphere containing chlorine , fluorine , or any other damaging chemicals ( other than in a normal residential environment ) , ( c ) unauthorized alteration or repair of the unit , which in turn affects its stability or performance , ( d ) failing to provideproper maintenance and service , ( e ) using other than a " Seacoast Protected " unit in a coastal environment , ( f ) using an incorrect power source , and ( g ) faulty installation or application of the unit . We shall not be liable for any incidental , consequential , or special damages or expenses in connection with any use or failure of this unit . We have not made and do not make any representation or warranty of fitness for a particular use or purpose and there is no implied condition of fitness for a particular use or purpose . We make no express warranties except as stated in this certificate . No one is authorized to change this certificate or to create for us any other obligation or liability in connection with this unit . Any implied warranties shall last for one year after the original purchase date . Some states and provincesdo not allow the exclusionor limitation of incidental or consequential damages or do not allow limitations on how long an implied warranty or condition lasts , so the above limitations or exclusions may not apply to you . The provisions of this warranty are in addition to and not a modification of or subtraction from the statutory warranties and other rights and remedies provided by law . Model No . Serial No . Date Purchased : Installation Location : FRIEDRICH AIR CONDITIONING CO . Post Office Box 1540 Date Installed : Installed by : 4200 N , PanAm Expressway SanAntonio , Texas 78295 - 1540 ( 210 ) 357 - 4400 FAX : ( 210 ) 357 - 4480 8 |