Page: 1 MODEL PH10 10 SEER 3 PHASE HEAT PUMP UNIT SIZES 048 , 060 — 4 AND 5 NOMINAL TONS Product Data FEATURES AVAILABLE Nominal sizes are available in 048 and 060 sizes 3 - PHASE ( SCROLL Control board that monitors the electrical phase to meet the needs of light commercial applications . and prevents compressor operation if wired COMPRESSOR incorrectly . UNITS ) MONITOR EFFICIENCY : With SEER of at least 10.0 and HSPF of 7.0 , these BOARD heat pump systems provide economy of operation through energy conservation . They recover heat for DISCHARGE Minimizes low frequency sound and pressure pul - indoor comfort from outdoor air during the heating sation generated by compressor discharge gas . season and , by automatically reversing the refrigerant MUFFLER system , remove indoor heat and excess humidity dur - DEFROST Incorporates a defrost relay , defrost timer and low - ing the cooling season . CONTROL voltage terminations . The defrost control is a time / CERTIFICATION : All models are listed with UL , ( U.S . and Can - BOARD : temperature initiation / termination control which ada ) , ARI , and CEC . includes 3 �eld - selectable time periods of 30 , 60 , and 90 minutes . The control includes built - in 5 - ELECTRICAL Units are offered in 208 – 230v 3 phase in the 048 minute compressor delay . and 060 sizes . COMPRESSOR : Designed speci�cally for heat pump duty , with energy FAN MOTOR : The totally enclosed fan motor means greater reli - ef�ciency during heating and cooling operation . Each ability under adverse weather conditions and compressor is hermetically sealed against contami - dependable performance for many years . Perma - nation to assure long life and dependable perfor - nent split capacitor type motors provide more eco - mance and externally mounted on rubber isolators for nomical operation . quiet operation . Continuous compressor operation is approved down to – 30 ° F ( – 34 ° C ) in the heating mode CABINET : The prepainted steel cabinet is protected under - and down to 55 ° F ( 12.8 ° C ) in the cooling mode . For neath by a galvanized coating and treated with a improved serviceability , all models are equipped with layer of zinc phosphate for a �nish that will last for a compressor terminal plug . many years . All screws on cabinet exterior are coated for a long - lasting , rust - resistant , quality SERVICE Both service valves are brass , front seat - appearance . VALVES : ing type with sweat connections . Valves are externally located so refrigerant tube connections can be made UNIT DESIGN : The copper tube , enhanced sine wave , aluminum �n quickly and easily . Each valve has a service port for coil is designed for optimum heat transfer . Vertical air ease of checking operating refrigerant pressures . discharge carries sound and hot condenser air up and away from adjacent patio areas and foliage . The base SERVICEABILTY : One panel provides access to electrical controls . pan is designed for easy removal of water , dirt , and Removal of top gives access to fan motor , compressor , leaves . and condenser coil . COMPONENTS : Includes a suction - tube accumulator that minimizes the amount of liquid refrigerant reaching the compres - LIMITED Standard 1 - year limited warranty on all parts and sor ; a low - pressure switch that stops the compressor WARRANTY : 5 - year limited warranty on compressor parts . if refrigerant charge is lost ; and an internal compres - sor relief valve on all sizes . Page: 2 ( in . ) Mounting 30 30 Dim x x 30 30 A97071 PAD Min 15 - 1 / 2 KNOCKOUT CONN 15 SUPPLY P HOLE KNOCKOUT LIQUID SUPPLY WITH DIA CONTROL 15 - 3 / 4 15 - 5 / 8 / 8 - IN . CONN DIA DIA HOLE N POWER / 8 - IN . / 8 - IN . 7 DIA LINE C CONN DIA FIELD PH10 / 8 - IN . 3 airflow . 3 / 8 ″ / 8 - IN . 1 13 - 3 / 4 FIELD AND 7 15 1 M 2 7 1 is proper / 4 ″ mode 1 29 - 9 / 16 29 - 9 / 16 1 unit L for heating in . cooling the units 12 DISCHARGE of side , of 26 - 3 / 8 26 - 3 / 8 CONN in in between position K ambient side ambient SQ one LINE A service AIR on VAPOR in . 14th operating 20 20 in . operating J 24 the to 6 DIA and unit , clearance is ( IN . ) . D 29 - 1 / 8 29 - 1 / 8 side , 125 ° F . designation outdoor outdoor above H gravity number . P 66 ° F . DIMENSIONS remaining in . max . in . B of Maximum 27 - / 12 27 - 1 / 4 30 Minimum is 48 Center model Series G 55 ° F , NOTES : IN mode Allow unit , AIR on L 1 . 2 . 3 . 4 . 5 . 23 - 1 / 2 23 - 1 / 2 DISCHARGE F K J 6 - 1 / 2 6 - 1 / 2 AIR E IN 7 / 8 7 / 8 D IN AIR AIR H G F 3 - 1 / 4 3 - 1 / 4 C M E 39 - 15 / 16 39 - 15 / 16 B DISCHARGE N DIA PLACES KNOCKOUTS TIEDOWN / 8 - IN . IN AIR 30 30 ( 2 ) A 3 AIR SERIES A A UNIT SIZE 048 060 — 2 — Page: 3 SPECIFICATIONS UNIT SIZE - SERIES 048 - A 060 - A Operating Weight ( Lb ) 221 238 Shipping Weight ( Lb ) 242 260 ELECTRICAL Unit Volts — Phase — Hertz 208 - 230 — 3 — 60 208 - 230 — 3 — 60 Operating Voltage Range 187 — 253 187 — 253 Unit Ampacity for Wire Sizing ( MCA ) 17.5 27.3 Min Wire Size 60 ° C Copper ( AWG ) * 14 10 Min Wire Size 75 ° C Copper ( AWG ) * 14 10 Max Wire Length 60 ° C Copper ( Ft ) †51 82 Max Wire Length 75 ° C Copper ( Ft ) †48 78 Max Branch Circuit Fuse Size ( Amps ) 25 35 Compressor Rated Load Amps 12.9 20.7 PH10 Compressor Locked Rotor Amps 91.0 137.0 Fan Motor Full Load Amps 1.4 1.4 COMPRESSOR AND REFRIGERANT Compressor Type Scroll Refrigerant Type R - 22 Refrigerant Charge ( Lb ) 9.38 10.50 OUTDOOR COIL & FAN Coil Face Area ( Sq Ft ) 22.40 Coil Fins per In . — Rows — Circuits 20 — 1 — 4 25 — 1 — 5 Fan Motor HP 1 / 4 1 / 4 Fan Motor RPM 1100 1100 Rated Airflow ( CFM ) 3300 3300 OPTIONAL EQUIPMENT Time - Delay Relay KAATD0101TDR Outdoor Thermostat KHAOT0301FST Secondary Outdoor Thermostat KHAOT0201SEC Cycle Protector KSACY0101AAA Compressor Crankcase Heater Standard Standard Compressor Start Assist — Capacitor / Relay N / A N / A Compressor Start Thermistor — PTC N / A N / A Compressor Sound Hood KSASH2101COP TXV Kits ( Hard Shutoff ) KSATX0701HSO KSATX1001HSO High - Pressure Switch KHAHI0101HPS Low - Ambient Pressure Switch KSALA0201R22 MotorMaster ® Control KSALA0401AAA Ball Bearing Fan Motor HC40GE232 Filter Drier ( RCD ) P504 - 8163S Evaporator Freeze Thermostat ‡ ‡ KAAFT0101AAA Isolation Relay ‡ ‡ KHAIR0101AAA Liquid - Line Solenoid Valve KHALS0401LLS Thermostat , Auto Changeover , Non - Programmable , ° F / ° C , 1 - Stage Heat , 1 - Stage Cool TSTATPPBHP01 - A Thermostat , Auto Changeover , 7 - Day Programmable , ° F / ° C , 1 - Stage Heat , 1 - Stage Cool TSTATPPPHP01 - A Outdoor Air Temperature Sensor ( For Programmable Thermostat ) TSTATXXSEN01 - B Backplate for Non - Programmable Thermostat TSTATXXBBP01 Backplate for Programmable Thermostat TSTATXXPBP01 Thermostat Conversion Kit ( 4 to 5 Wire ) — 10 pack TSTATXXCNV10 * The ampacity of non - metallic ( NM ) sheathed cable shall be that of 60 ° C ( 140 ˚ F ) conductors per NEC 1999 , Article 336 - 26 . If wire used is other than speci�ed in chart , refer to applicable tables available in 1999 NEC . Copper wire must be used from disconnect to unit . †Length shown is as measured 1 way along the wire path between the unit and the service panel for a voltage drop not to exceed 2 % . ‡ Units may use fuses or circuit breakers ( U.S . only ) . ‡ ‡ Consult low - ambient control Installation Instructions for application . N / A — Not Applicable — 3 — Page: 4 REFRIGERANT METERING DEVICE AND LINE SET DATA UNIT SIZE - SERIES 048 - A 060 - A METERING DEVICE Outdoor Piston Size 70 86 Indoor Piston Size * 76 96 Required Subcooling ( ° F ) †15 10 REFRIGERANT LINE CONNECTION DIAMETERS ( IN . ID ) Liquid Line 3 / 8 Vapor Line 7 / 8 7 / 8 REFRIGERANT LINE DIAMETERS ( IN . OD ) Liquid Line ( All Applications Maximum Diameter ) 3 / 8 Vapor Line ( 0 – 80 Ft Line Lengths ) 7 / 8 1 - 1 / 8 Vapor Line ( Long - Line Applications Maximum Diameter ) 1 - 1 / 8 1 - 1 / 8 PH10 * Piston listed is for any approved coil combination . †Charging subcooling for indoor TXV - type expansion device . ISO 9001 : 2000 REGISTERED SOUND RATING ( dBA ) UNIT SIZE – SERIES SOUND RATING 048 - A 80 060 - A 80 . MODEL NUMBER NOMENCLATURE 048 000 A A AA PH10 P R Variations Type of Unit Series PH10 – Electric Heat Pump Variations Electrical Supply A — Standard Unit P — 208 / 230 - 3 - 60 Heating Capacity Refrigerant – R22 Nominal Cooling Capacity 048 – 4 ton 060 – 5 ton OPTIONAL EQUIPMENT USAGE GUIDELINE REQUIRED FOR REQUIRED FOR LOW - AMBIENT APPLICATIONS LONG - LINE APPLICATIONS * ACCESSORY ( Below 55 ° F ) ( Over 80 Ft ) Crankcase Heater Yes Yes Evaporator Freeze Thermostat Yes No Accumulator No No MotorMaster ® Control or Yes No Low - Ambient Pressure Switch See Low - Ambient No Wind Baffle Instructions Support Feet Recommended No Liquid - Line Solenoid Valve See Long - Line or No Application Hard Shutoff TXV Guideline Ball Bearing Fan Motor Yes ‡ No * For tubing line sets between 80 and 200 ft ( 250 ft total equivalent length ) , refer to the Residential Split - System Long - Line Application Guideline . ‡ Required for low - ambient controller ( full modulation feature ) and MotorMaster ® Control only . — 4 — Page: 5 OPTIONAL EQUIPMENT DESCRIPTION AND USAGE ( Listed Alphabetically ) 1 . Ball Bearing Fan Motor A fan motor with ball bearings which permits speed reduction while maintaining bearing lubrication . SUGGESTED USE : Required on all units where Low - Ambient Controller ( full modulation feature ) or MotorMaster ® Control has been added . 2 . Compressor Crankcase Heater An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles . Improves compressor lubrication on restart and minimizes chance of refrigerant slugging . May or may not include a thermostat control . SUGGESTED USE : When interconnecting tube length exceeds 80 ft . When unit will be operated below 55 ° F ( 12.8 ° C ) outdoor air temperature . ( Use with low - ambient controller . ) All commercial installations . 3 . Compressor Sound Hood Wraparound sound attenuation cover for the compressor . Reduces unit sound level by about 2 dBA . SUGGESTED USE : Unit installed closer than 15 ft to quiet areas — bedrooms , etc . Unit installed between 2 houses less than 10 ft apart . 4 . Cycle Protector Solid - state timing device which prevents compressor rapid recycling . Control provides an approximate 5 - minute delay after power to the compressor has been interrupted for any reason , including normal room thermostat cycling . SUGGESTED USE : Installations in areas where power interruptions are frequent . Where user is likely to play with room thermostat . All commercial installations . PH10 Installations where interconnecting tube length exceeds 80 ft . High - rise applications . 5 . Evaporator Freeze Thermostat An SPST temperature actuated switch which stops unit operation when evaporator reaches freeze - up conditions . SUGGESTED USE : All units where Low - Ambient Controller has been added . 6 . Filter Drier — Bi - Flow A device for removing contaminants from refrigerant circulating in a heat pump system : 2 - direction flow . SUGGESTED USE : All �eld - connected split - system heat pumps . 7 . High - Pressure Switch Auto reset SPST switch activated by refrigerant pressure on high side of refrigerant circuit . Cycles compressor off if refrigerant pressure rises to about 426 ± 7 psig and resets at 320 ± 20 psig . Provides protection against compressor damage due to loss of outdoor airflow . To prevent rapid compressor recycling , Cycle Protector can be used with this switch . SUGGESTED USE : Installations exposed to very ‘ ‘ dirty ’ ’ outdoor air . Installations where condenser inlet air temperature exceeds 125 ° F ( 51.7 ° C ) . 8 . Isolation Relay An SPDT relay which switches the Low - Ambient Controller out of the outdoor fan motor circuit when the heat pump switches to heating mode . SUGGESTED USE : All heat pumps where Low - Ambient Controller has been added . 9 . Liquid - Line Solenoid Valve An electrically operated shutoff valve to be installed at the outdoor or indoor unit ( depending on tubing con�guration ) which stops and starts refrigerant liquid flow in response to compressor operation . Maintains a column of refrigerant liquid ready for action at next compressor operation cycle . SUGGESTED USE : For improved system performance in heat pumps for certain combinations of indoor and outdoor units . Refer to ARI Unitary Directory . In certain long - line applications . Refer to the Residential Split System Long - Line Application Guideline . 10 . Low - Ambient Pressure Switch A long life pressure switch which is mounted to outdoor unit service valve . It is designed to cycle the outdoor fan motor in order to maintain head pressure within normal operating limits ( approximately 100 psig to 225 psig ) . The control will maintain working head pressure at low - ambient temperatures down to 0 ° F ( – 17.8 ° C ) when properly installed . SUGGESTED USE : Cooling operation at outdoor temperatures below 55 ° F ( 12.8 ° C ) . 11 . MotorMaster ® Control A fan speed control device activated by a temperature sensor . Designed to control condenser fan motor speed in response to the saturated , condensing temperature during operation in cooling mode only . For outdoor temperatures down to – 20 ° F , it maintains condensing temperature at 100 ° F ± 10 ° F . SUGGESTED USE : Cooling operation at outdoor temperatures below 55 ° F ( 12.8 ° C ) . All commercial installations . 12 . Outdoor Air Temperature Sensor A device that allows the temperature at a remote location ( outdoors ) to be displayed at the thermostat . SUGGESTED USE : All Payne programmable thermostats . 13 . Outdoor Thermostat An SPDT temperature - actuated switch which turns on supplemental electric heaters when outdoor air temperature drops below set point . SUGGESTED USE : Heat pump installations with multiple - stage supplemental heaters . 14 . Secondary Outdoor Thermostat An SPDT temperature actuated switch which turns on third - stage of supplemental electric heaters when outdoor air temperature drops below the second - stage set point . SUGGESTED USE : Heat pump installations where 3 - stage operation of supplemental heaters is desired . 15 . Thermostatic Expansion Valve ( TXV ) — Bi - Flow A modulating flow control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the evaporator . Kit includes valve , adapter tubes , and external equalizer tube . SUGGESTED USE : For improved system performance in cooling mode for certain combinations of indoor and outdoor units . Refer to ARI Unitary Directory . 16 . Time - Delay Relay An SPST delay relay which briefly continues operation of the indoor blower motor to provide additional cooling after the compressor cycles off . SUGGESTED USE : For improved ef�ciency ratings for certain combinations of indoor and outdoor units . Refer to ARI Unitary Directory . — 5 — Page: 6 COMBINATION RATINGS ARI STANDARD RATINGS * * Cooling Heating SEER High - Temp Low - Temp Factory - Payne eGassory Supplied FurnacsR †UNIT SIZE - INDOOR Enhance - Standard Accessory or AcceD TC EER SERIES UNIT ment Rating TXV T TC COP TC COP HSPF * PF1MNB048 45,500 TDR 10.00 — — 9.15 47,000 3.20 30,200 2.34 7.20 CAR * * 4817A * * 45,000 TXV — — 10.00 9.20 46,500 3.28 28,600 2.44 7.200000 CAR * * 4821A * * 45,000 TXV — — 10.00 9.20 46,500 3.28 29,000 2.44 7.2222 CAR * * 4824A * * 45,000 TXV — — 10.00 9.20 46,500 3.28 29,000 2.44 7 . . . CAR * * 6021A * * 47,000 TXV — — 10.20 9.50 45,500 3.30 29,000 2.46 77 CAR * * 6024A * * 47,000 TXV — — 10.20 9.40 45,500 3.30 29,000 2.46 CC5A / CD5AA060 45,000 NONE — 10.00 10.00 9.25 46,500 3.06 29,800 2.30 7.20 CC5A / CD5AC048 43,500 NONE — 10.00 10.00 9.15 46,000 2.94 29,400 2.26 7.00 CC5A / CD5AW048 45,000 NONE — 10.00 10.00 9.15 46,500 3.12 29,800 2.32 7.200PH10 CC5A / CD5AW060 46,000 NONE — 10.00 10.00 9.40 47,000 3.22 29,800 2.36 7.2 CD5AA048 45,000 NONE — 10.00 10.00 9.20 46,500 3.12 29,800 2.32 7.20 CE3AA048 45,000 NONE — 10.00 10.00 9.35 47,000 3.12 29,600 2.34 7.200 CE3AA060 46,000 NONE — 10.00 10.00 9.45 47,000 3.18 29,800 2.38 7.5 CF5AA048 44,500 NONE — 10.00 10.00 9.30 46,500 2.94 29,000 2.28 7.20 CK3BA048 45,000 NONE — 10.00 10.00 9.25 46,500 3.16 29,800 2.36 7.200 CK3BA060 45,000 NONE — 10.00 10.00 9.40 46,500 3.30 30,000 2.40 7.2 CK5A / CK5BA048 45,000 NONE — 10.00 10.00 9.25 46,500 3.16 29,800 2.36 7.200 048 - A CK5A / CK5BA060 45,000 NONE — 10.00 10.00 9.40 46,500 3.30 30,000 2.40 7.2 CK5A / CK5BT048 45,000 NONE — 10.00 10.00 9.25 46,500 3.16 29,800 2.36 7.200 CK5A / CK5BT060 45,000 NONE — 10.00 10.00 9.40 46,500 3.30 30,000 2.40 7.2 CK5A / CK5BW048 45,000 NONE — 10.00 10.00 9.25 46,500 3.16 29,800 2.36 7.20 CK5A / CK5BX060 46,000 NONE — 10.00 10.00 9.50 47,000 3.28 30,000 2.42 7.20 CNRV * 4821A * * 45,000 TXV — — 10.00 9.20 46,500 3.28 29,000 2.44 7.2000 CNRV * 4824A * * 45,000 TXV — — 10.00 9.20 46,500 3.28 29,000 2.44 7.22 CNRV * 6024A * * 47,000 TXV — — 10.20 9.50 45,500 3.28 29,000 2.46 7 . CNRH * 4821A * * 46,000 TXV — — 10.00 9.40 46,500 3.28 29,000 2.44 7.200 CNRH * 6024A * * 47,000 TXV — — 10.20 9.50 45,500 3.28 29,000 2.46 7.2 CNRF * 4818A * * 45,000 TXV — — 10.00 9.20 46,000 3.18 28,600 2.40 7.20 CSRH * 4812A * * 46,000 TXV — — 10.00 9.20 46,500 3.32 29,000 2.46 7.200 CSRH * 6012A * * 47,000 TXV — — 10.20 9.50 45,500 3.36 29,000 2.48 7.2 PF1MNB060 46,500 TDR 10.00 — — 9.20 47,000 3.22 30,400 2.36 7.500 PF1MNB070 47,000 TDR 10.00 — — 9.45 42,500 3.30 30,400 2.42 7.5 PF1MNC048 46,000 TDR & TXV 10.00 — — 9.30 47,000 3.30 29,400 2.44 7.200 PF1MNC060 47,000 TDR & TXV 10.00 — — 9.40 46,000 3.32 29,400 2.44 7.2 * PF1MNB060 56,000 TDR 10.10 — — 9.00 58,000 3.16 38,500 2.38 7.50 CAR * * 6021A * * 55,000 TXV — — 10.20 9.40 56,000 3.20 38,500 2.48 7.200 CAR * * 6024A * * 56,000 TXV — — 10.50 9.40 55,000 3.18 39,000 2.48 7.2 CC5A / CD5AA060 53,500 NONE — 10.20 10.20 9.15 56,000 2.94 37,200 2.30 7.00 CC5A / CD5AW060 55,500 NONE — 10.50 10.50 9.30 56,500 3.14 37,600 2.40 7.50 CE3AA060 56,000 NONE — 10.20 10.20 9.35 56,500 3.16 37,600 2.40 7.500 CK3BA060 53,500 NONE — 10.20 10.20 9.30 56,000 3.06 37,200 2.36 7.0 060 - A CK5A / CK5BA060 53,500 NONE — 10.20 10.20 9.30 56,000 3.06 37,200 2.36 7.00 CK5A / CK5BT060 53,500 NONE — 10.20 10.20 9.30 56,000 3.06 37,200 2.36 7.00 CK5A / CK5BX060 55,500 NONE — 10.50 10.50 9.40 56,500 3.20 37,800 2.42 7.50 CNRV * 6024A * * 56,000 TXV — — 10.50 9.40 56,000 3.26 39,000 2.48 7.20 CNRH * 6024A * * 56,000 TXV — — 10.50 9.40 56,000 3.26 39,000 2.48 7.20 CSRH * 6012A * * 56,000 TXV — — 10.50 9.50 56,000 3.30 39,000 2.50 7.20 PF1MNB070 56,500 TDR 10.50 — — 9.00 57,000 3.32 38,000 2.46 7.50 PF1MNC060 57,000 TDR & TXV 10.50 — — 9.50 56,500 3.22 39,000 2.46 7.50 * Outdoor section / indoor section combination tested in accordance with DOE test procedures for heat pumps . Ratings for other combinations are determined under DOE computer simulation procedures . †In most cases , only 1 method should be used to achieve TDR function . Using more than 1 method in a system may cause degradation in performance . Use either the accessory Time - Delay Relay KAATD0101TDR or a furnace equipped with TDR . All Payne furnaces are equipped with TDR . ‡ Requires hard shutoff TXV ; based on computer simulation . * * Ratings are net values reflecting the effects of circulating fan heat . Supplemental electric heat is not included . Ratings are based on : Cooling Standard : 80 ° F ( 27 ° C ) db , 67 ° F ( 19 ° C ) wb indoor entering air temperature and 95 ° F ( 35 ° C ) db air entering outdoor unit . High - Temperature Heating Standard : 70 ° F ( 21 ° C ) db indoor entering air temperature and 47 ° C ( 8 ° C ) db 43 ° F ( 6 ° C ) wb air entering outdoor unit . Low - Temperature Heating Standard : 70 ° F ( 21 ° C ) db indoor entering air temperature and 17 ° F ( – 9 ° C ) db , 15 ° F ( – 10 ° C ) wb air entering outdoor unit . COP — Coef�cient of Performance EER — Energy Ef�ciency Ratio HSPF — Heating Seasonal Performance Factor SEER — Seasonal Energy Ef�ciency Ratio TC — Total Capacity ( Btuh ) TDR — Time - Delay Relay TXV — Thermostatic Expansion Valve — 6 — Page: 7 DETAILED COOLING CAPACITIES * CONDENSER ENTERING AIR TEMPERATURES ° F EVAP AIR 85 95 105 115 Capacity Capacity Capacity Capacity Total Total Total Total MBtuh †MBtuh †MBtuh †MBtuh †Sys Sys Sys Sys CFM EWB kW * * kW * * kW * * Total Sens ‡ Total Sens ‡ Total Sens ‡ Total Sens ‡ kW * * PH10PR048 - A Outdoor Section With PF1MNB048 Indoor Section 72 51.2 26.1 4.53 48.8 25.3 4.96 46.4 24.4 5.44 43.7 23.5 5.95 67 46.9 33.8 4.44 44.7 32.9 4.87 42.4 32.0 5.33 40.0 31.0 5.84566 1500 63 ††43.7 32.8 4.38 41.6 31.9 4.80 39.4 30.9 5.26 37.0 29.9 5.777 62 43.2 41.0 4.37 41.2 40.0 4.79 39.2 38.8 5.25 37.1 37.1 5 . . 57 42.5 42.5 4.35 40.8 40.8 4.78 39.0 39.0 5.25 37.1 37.1 5 72 51.5 26.7 4.58 49.1 25.9 5.01 46.6 25.0 5.49 43.9 24.1 6.009022 67 47.3 34.8 4.49 45.0 33.9 4.92 42.6 33.0 5.39 40.2 32.0 5.8888 1600 63 ††44.0 33.7 4.42 41.8 32.8 4.85 39.6 31.8 5.31 37.2 30.8 5 . . . 62 43.6 42.3 4.42 41.6 41.1 4.84 39.6 39.6 5.31 37.7 37.7 55 PH10 57 43.2 43.2 4.41 41.5 41.5 4.84 39.6 39.6 5.31 37.7 37.7 72 51.8 27.3 4.63 49.4 26.4 5.06 46.8 25.5 5.54 44.1 24.6 6.054588 67 47.6 35.8 4.54 45.3 34.9 4.97 42.9 34.0 5.44 40.4 33.0 5.9888 1700 63 ††44.2 34.6 4.47 42.1 33.7 4.90 39.8 32.8 5.36 37.4 31.7 5 . . . 62 44.0 43.4 4.47 42.1 42.0 4.90 40.2 40.2 5.37 38.2 38.2 55 57 43.8 43.8 4.46 42.0 42.0 4.90 40.2 40.2 5.37 38.2 38.2 Multipliers for Determining the Performance With Other Indoor Sections Cooling Cooling Indoor Indoor Section Size Capacity Power Section Size Capacity Power CAR * * 4817A * * 0.98 0.94 CK5A / CK5BT 048 0.99 0.98 4821A * * 0.98 0.95 060 1.01 0.99 4824A * * 0.98 0.96 CK5A / CK5BW 048 0.99 0.98 6021A * * 1.00 0.96 CK5A / CK5BX 060 1.03 1.00 6024A * * 1.00 0.96 CNRV * 4821A * * 0.98 0.95 CC5A / CD5AA 060 0.99 0.99 4824A * * 0.98 0.95 CC5A / CD5AC 048 0.97 0.98 6024A * * 1.00 0.96 CC5A / CD5AW 048 0.98 0.98 CNRH * 4821A * * 0.98 0.95 CD5AA 048 0.98 0.98 6024A * * 1.00 0.96 CE3AA 048 0.99 0.98 CNRF * 4818A * * 0.98 0.96 060 1.02 0.98 CSRH * 4812A * * 0.98 0.95 CF5AA 048 1.00 0.98 6012A * * 1.00 0.95 CK3BA 048 0.99 0.98 PF1MNB 048 1.00 1.00 060 1.03 1.00 060 1.02 1.02 CK5A / CK5BA 048 0.99 0.98 070 1.06 1.02 060 1.01 0.99 PF1MNC 048 0.98 0.96 — — — 060 1.00 0.97 See notes on page 8 . — 7 — Page: 8 DETAILED COOLING CAPACITIES * Continued CONDENSER ENTERING AIR TEMPERATURES ° F EVAP AIR 85 95 105 115 Capacity Capacity Capacity Capacity Total Total Total Total MBtuh †MBtuh †MBtuh †MBtuh †Sys Sys Sys Sys CFM EWB kW * * kW * * kW * * Total Sens ‡ Total Sens ‡ Total Sens ‡ Total Sens ‡ kW * * PH10PR060 - A Outdoor Section With PF1MNB060 Indoor Section 72 64.2 32.6 5.73 61.2 31.5 6.25 58.0 30.4 6.83 54.7 29.3 7.46 67 58.6 42.4 5.61 55.8 41.2 6.13 52.8 40.1 6.69 49.7 38.9 7.31900 1900 63 ††54.4 41.0 5.53 51.8 39.9 6.04 49.0 38.7 6.60 46.0 37.4 7.122 62 53.7 51.5 5.51 51.3 50.2 6.03 48.7 48.6 6.59 46.3 46.3 7 . . 57 53.0 53.0 5.50 50.9 50.9 6.02 48.7 48.7 6.59 46.3 46.3 7 72 64.5 33.2 5.79 61.4 32.1 6.32 58.1 31.0 6.89 54.9 29.8 7.527678 67 58.9 43.4 5.67 56.0 42.2 6.19 53.0 41.0 6.76 49.9 39.9 7.3222 2000 63 ††54.7 42.0 5.59 52.0 40.8 6.10 49.1 39.6 6.66 46.2 38.3 7 . . . 62 54.2 52.8 5.58 51.6 51.3 6.09 49.2 49.2 6.66 46.8 46.8 77 PH10 57 53.7 53.7 5.57 51.5 51.5 6.09 49.2 49.2 6.66 46.8 46.8 72 64.8 33.7 5.85 61.6 32.6 6.38 58.4 31.5 6.95 55.0 30.4 7.583255 67 59.1 44.4 5.73 56.1 43.2 6.25 53.1 42.0 6.82 50.0 40.8 7.4333 2100 63 ††55.0 42.9 5.64 52.1 41.7 6.16 49.4 40.5 6.72 46.3 39.2 7 . . . 62 54.6 53.9 5.64 52.2 52.1 6.16 49.8 49.8 6.73 47.3 47.3 77 57 54.3 54.3 5.63 52.1 52.1 6.16 49.7 49.7 6.73 47.3 47.3 Multipliers for Determining the Performance With Other Indoor Sections Cooling Cooling Indoor Indoor Section Size Capacity Power Section Size Capacity Power CAR * * 6021A * * 1.00 0.94 CK5A / CK5BX 060 1.01 0.96 6024A * * 1.00 0.94 CNRV * 6024A * * 1.00 0.95 CC5A / CD5AA 060 0.96 0.96 CNRH * 6024A * * 1.00 0.95 CC5A / CD5AW 060 0.99 0.97 CSRH * 6012A * * 1.00 0.94 CE3AA 060 1.01 0.97 PF1MNB 060 1.00 1.00 CK3BA 060 1.01 0.96 070 1.03 0.99 CK5A / CK5BA 060 0.97 0.95 PF1MNC 060 1.00 0.97 CK5A / CK5BT 060 0.97 0.95 — — — NOTE : When the required data fall between the published data , interpolation may be performed . Extrapolation is not an acceptable practice . * Detailed cooling capacities are based on indoor and outdoor unit at the same elevation and connected by 25 ft ( 4.59m ) of tubing . If other than 25 ft ( 4.59m ) of tubing is used and / or indoor unit is located above outdoor unit , a slight variation in capacity may occur . †Total and sensible capacities are net capacities . Blower motor heat has been subtracted . ‡ Sensible capacities shown are based on 80 ° F ( 27 ° C ) entering air at the indoor coil . For sensible capacities at other than 80 ° F ( 27 ° C ) , deduct 835 Btuh ( 245 kW ) per 1000 CFM ( 480 L / S ) of indoor coil air for each degree below 80 ° F ( 27 ° C ) , or add 835 Btuh ( 245 kW ) per 1000 CFM ( 480 L / S ) of indoor coil air per degree above 80 ° F ( 27 ° C ) . * * System kW is total of indoor and outdoor unit kilowatts . ††At TVA rating indoor condition ( 75 ° F edb / 63 ° F ewb ) . All other indoor air temperatures are at 80 ° F edb . — 8 — Page: 9 HEAT PUMP HEATING PERFORMANCE OUTDOOR COIL ENTERING AIR TEMPERATURES ° F INDOOR AIR – 3 7 17 27 37 47 57 67 Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total MBtuh †Pwr MBtuh †Pwr MBtuh †Pwr MBtuh †Pwr MBtuh †Pwr MBtuh †Pwr MBtuh †Pwr MBtuh †Pwr EDB CFM Total Int kW ‡ Total Int kW ‡ Total Int kW ‡ Total Int kW ‡ Total Int kW ‡ Total Int kW ‡ Total Int kW ‡ Total Int kW ‡ PH10PR048 - A Outdoor Section With PF1MNB048 Indoor Section 1500 26.4 24.2 3.76 30.0 27.5 3.79 33.5 30.6 3.80 37.2 33.0 3.83 40.9 37.2 3.87 45.2 45.2 3.96 50.4 50.4 4.12 53.2 53.2 4.1711 65 1600 26.5 24.4 3.79 30.1 27.7 3.81 33.7 30.7 3.82 37.4 33.2 3.84 41.1 37.4 3.87 45.5 45.5 3.95 50.6 50.6 4.10 52.8 52.8 4.11 1700 26.7 24.6 3.82 30.3 27.9 3.83 33.9 30.9 3.84 37.6 33.4 3.85 41.3 37.6 3.88 45.7 45.7 3.96 50.8 50.8 4.09 53.2 53.2 4 . 1500 26.0 23.9 3.90 29.6 27.2 3.94 33.2 30.3 3.96 36.8 32.7 3.99 40.5 36.8 4.04 44.7 44.7 4.13 49.9 49.9 4.29 53.6 53.6 4.4163 70 1600 26.2 24.1 3.93 29.8 27.4 3.96 33.4 30.5 3.98 37.0 32.9 4.00 40.7 37.0 4.04 45.0 45.0 4.12 50.2 50.2 4.29 53.6 53.6 4.33 1700 26.4 24.3 3.96 30.0 27.6 3.98 33.6 30.6 4.00 37.2 33.1 4.01 40.9 37.2 4.04 45.2 45.2 4.12 50.4 50.4 4.28 53.5 53.5 4 . 1500 25.5 23.4 4.03 29.3 26.9 4.09 32.9 30.0 4.13 36.5 32.4 4.17 40.1 36.5 4.21 44.2 44.2 4.30 49.3 49.3 4.47 53.6 53.6 4.6404 75 1600 25.7 23.6 4.06 29.5 27.1 4.12 33.1 30.2 4.14 36.7 32.6 4.17 40.3 36.7 4.21 44.5 44.5 4.29 49.6 49.6 4.46 53.7 53.7 4.65 1700 25.9 23.8 4.09 29.7 27.3 4.14 33.3 30.3 4.16 36.9 32.7 4.18 40.5 36.8 4.22 44.7 44.7 4.29 49.8 49.8 4.45 53.4 53.4 4 . PH10 Multipliers for Determining the Performance With Other Indoor Sections Heating Heating Indoor Indoor Section Size Capacity Power Section Size Capacity Power CAR * * 4817A * * 0.96 0.93 CK5A / CK5BT 048 0.99 1.00 4821A * * 0.96 0.93 060 1.00 1.01 4824A * * 0.96 0.94 CK5A / CK5BW 048 0.99 1.00 6021A * * 0.79 0.88 CK5A / CK5BX 060 0.98 0.96 6024A * * 0.79 0.88 CNRV * 4821A * * 0.96 0.93 CC5A / CD5AA 060 0.99 1.03 4824A * * 0.96 0.93 CC5A / CD5AC 048 0.96 1.03 6024A * * 0.88 0.92 CC5A / CD5AW 048 0.99 1.02 CNRH * 4821A * * 0.96 0.93 CD5AA 048 0.99 1.02 6024A * * 0.88 0.92 CE3AA 048 0.99 1.01 CNRF * 4818A * * 0.96 0.96 060 0.97 0.96 CSRH * 4812A * * 0.96 0.93 CF5AA 048 0.95 1.00 6012A * * 0.85 0.89 CK3BA 048 0.99 1.00 PF1MNB 048 1.00 1.00 060 0.98 0.96 060 0.97 0.97 CK5A / CK5BA 048 0.99 1.00 070 0.90 0.92 060 1.00 1.01 PF1MNC 048 0.94 0.94 — — — 060 0.82 0.90 See notes on page 10 . — 9 — Page: 10 HEAT PUMP HEATING PERFORMANCE Continued OUTDOOR COIL ENTERING AIR TEMPERATURES ° F INDOOR AIR – 3 7 17 27 37 47 57 67 Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total MBtuh †Pwr MBtuh †Pwr MBtuh †Pwr MBtuh †Pwr MBtuh †Pwr MBtuh †Pwr MBtuh †Pwr MBtuh †Pwr EDB CFM Total Int kW ‡ Total Int kW ‡ Total Int kW ‡ Total Int kW ‡ Total Int kW ‡ Total Int kW ‡ Total Int kW ‡ Total Int kW ‡ PH10PR060 - A Outdoor Section With PF1MNB060 Indoor Section 1900 28.0 25.8 4.36 32.8 30.2 4.51 38.2 34.8 4.67 44.0 39.1 4.86 50.9 46.3 5.12 59.4 59.4 5.50 69.7 69.7 6.06 79.0 79.0 6.3517 65 2000 28.2 25.9 4.40 33.0 30.4 4.54 38.4 35.0 4.70 44.3 39.3 4.89 51.2 46.6 5.14 59.7 59.7 5.52 70.0 70.0 6.08 78.8 78.8 6.54 2100 28.4 26.1 4.44 33.2 30.5 4.58 38.6 35.2 4.73 44.5 39.5 4.92 51.4 46.8 5.17 59.9 59.9 5.54 70.3 70.3 6.11 78.5 78.5 6 . 1900 27.7 25.5 4.51 32.5 29.8 4.68 37.8 34.4 4.86 43.6 38.7 5.06 50.3 45.8 5.32 58.7 58.7 5.70 68.8 68.8 6.27 78.7 78.7 6.8752 70 2000 27.9 25.6 4.55 32.7 30.0 4.71 38.0 34.6 4.88 43.8 38.9 5.08 50.6 46.0 5.34 59.0 59.0 5.72 69.0 69.0 6.28 78.9 78.9 6.88 2100 28.1 25.8 4.59 32.9 30.2 4.75 38.2 34.8 4.91 44.0 39.1 5.11 50.8 46.2 5.36 59.3 59.3 5.74 69.4 69.4 6.31 78.8 78.8 6 . 1900 27.3 25.1 4.66 32.1 29.5 4.85 37.4 34.1 5.05 43.1 38.3 5.26 49.7 45.3 5.53 58.0 58.0 5.92 68.0 68.0 6.49 78.2 78.2 7.1669 75 2000 27.5 25.3 4.70 32.3 29.7 4.89 37.6 34.3 5.07 43.3 38.5 5.28 50.0 45.5 5.55 58.3 58.3 5.94 68.3 68.3 6.50 78.4 78.4 7.11 2100 27.7 25.5 4.74 32.5 29.9 4.92 37.8 34.5 5.10 43.6 38.7 5.31 50.2 45.7 5.57 58.5 58.5 5.95 68.6 68.6 6.52 78.8 78.8 7 . Multipliers for Determining the Performance With Other Indoor Sections Heating Heating Indoor Indoor Section Size Capacity Power Section Size Capacity Power Heating Heating Indoor Indoor Section Size Capacity Power Section Size Capacity Power CAR * * 6021A * * 0.97 0.94 CK5A / CK5BX 060 0.98 0.97 6024A * * 0.96 0.93 CNRV * 6024A * * 0.98 0.95 CC5A / CD5AA 060 0.97 1.03 CNRH * 6024A * * 0.98 0.95 CC5A / CD5AW 060 0.98 1.00 CSRH * 6012A * * 0.98 0.93 CE3AA 060 0.98 0.98 PF1MNB 060 1.00 1.00 CK3BA 060 0.98 0.97 070 1.00 0.96 CK5A / CK5BA 060 0.97 1.00 PF1MNC 060 0.97 0.95 CK5A / CK5BT 060 0.97 1.00 — — — NOTE : When the required data fall between the published data , interpolation may be performed . Extrapolation is not an acceptable practice . †The Btuh heating capacity values shown are net integrated values from which the defrost effect has been subtracted . The Btuh heating from supplement heaters should be added to those values to obtain total system capacity . ‡ The kW values include the compressor , outdoor fan motor , and indoor blower motor . The kW from supplement heaters should be added to these values to obtain total system kilowatts . EDB — Entering Dry Bulb SYSTEM DESIGN 1 . Intended for outdoor installation with free air inlet and outlet . Outdoor fan external static pressure available is less than 0.01 - in . wc . 2 . Minimum outdoor operating air temperature for cooling mode without low - ambient operation accessory is 55 ° F ( 12.8 ° C ) . 3 . Maximum outdoor operating air temperature for cooling mode is 115 ° F ( 46.1 ° C ) . ) . 4 . Minimum outdoor operating air temperature for heating mode is – 30 ° F C ( – 34.4 ° C ) . 5 . Maximum outdoor operating air temperature for heating mode is 66 ° F ( 18.9 ° 6 . For reliable operation , unit should be level in all horizontal planes.r 7 . Maximum elevation of indoor coil above or below base of outdoo unit is : indoor coil above = 60 ft , indoor coil below = 200 ft . ( See items 8 and 9 following . ) connecting 8 . For inter refrigerant tube lengths greater than 80 ft or 20 ft vertical differential ( 250 ft total equivalent length ) , consult the Residential Split - System Long - Line Application Guideline available from equipment distributor.lve 9 . IF ANY refrigerant tubing is buried , provide a minimum 6 - in . vertical rise to the va connections at the unit . Refrigerant tubing lengths up to 36 in . may be buried without further tconsideration . 10 . Use only copper wire for electric connection a unit . Aluminum and clad aluminum are not acceptable for the type of connector provided . © Payne Heating & Cooling Systems 7310 W . Morris St . Indianapolis , IN 46231 Printed in U.S.A . edition date : 3 / 06 Catalog No . SS - PH10 - 09 Manufacturer reserves the right to change , at any time , specifications or designs without notice and obligations Replaces : SS - PH10 - 08 — 10 — |