| Home | | Register Login | | Wanted Manuals | | MarketPlace | | Members Area | | Manuals Manufacturer Directory | | UPC Lookup | | Information Pages | | Policy |
|
|
Register / log-in to add to your Hammerwall Collection. Manual Location
The Search Results for the Search Section to the left will appear here.
Page: 1 Heating Check Chart 10 8SEERystemp – 060 PH10JA Split - St Hea Pum1 Sizes 0 HEATING CHECK CHART FIELD OPERATING PRESSURE CHARGING TABLE FIXED RESTRICTOR ( HIGH PRESSURE @ VAPOR VALVE , SUCTION PRESSURE @ SUCTION SERVICE PORT ) INDOOR OUTDOOR TEMP . ° F DRY BULB / WET BULB DRY UNIT 60 / 57 50 / 47 40 / 38 30 / 28 20 / 18 10 / 9 0 / - 1 BULB 218 203 188 173 159 144 129 HIGH 60 ° 59 52 45 38 32 25 18 SUCT 252 235 218 202 185 168 152 HIGH 70 ° 018 63 55 48 40 33 25 17 SUCT 284 265 247 228 210 191 173 HIGH 80 ° 66 58 49 41 33 25 17 SUCT HIGH 192 183 175 159 143 136 128 60 ° SUCT 54 51 47 39 32 26 20 HIGH 222 211 200 183 166 156 146 70 ° 024 SUCT 58 54 49 41 33 27 20 HIGH 252 236 221 205 189 178 167 80 ° SUCT 62 55 49 41 34 27 21 HIGH 203 190 178 165 152 140 127 60 ° SUCT 58 51 45 39 32 26 19 HIGH 231 217 203 189 175 161 147 70 ° 030 SUCT 62 55 48 41 33 26 19 HIGH 262 246 231 215 199 184 168 80 ° SUCT 65 57 50 42 35 27 20 199 190 180 166 151 140 129 HIGH 60 ° 56 51 46 38 30 24 18 SUCT 228 214 207 190 172 161 150 HIGH 70 ° 036 60 54 48 40 31 24 18 SUCT 260 247 233 211 190 182 174 HIGH 80 ° 63 57 50 41 32 25 19 SUCT HIGH 244 226 208 190 172 153 135 60 ° SUCT 63 55 47 39 32 24 16 HIGH 275 256 236 217 198 178 159 70 ° 042 SUCT 65 57 49 40 32 24 16 HIGH 303 283 262 242 222 201 181 80 ° SUCT 66 58 49 41 33 25 16 HIGH 205 192 179 166 153 140 127 60 ° SUCT 56 49 42 35 28 21 14 HIGH 237 222 208 193 178 163 148 70 ° 048 SUCT 59 52 44 37 29 21 14 HIGH 279 261 243 225 206 188 170 80 ° SUCT 66 57 48 39 30 22 13 HIGH 211 198 186 169 153 146 140 60 ° SUCT 53 47 41 33 25 20 15 HIGH 243 225 206 193 180 171 162 70 ° 060 SUCT 57 48 40 34 27 21 15 HIGH 278 259 240 223 206 196 186 80 ° SUCT 59 51 44 36 28 22 16 CAUTION Compressor damage may occur if system is over - charged . OPERATION To check system operation during heating cycle , use this table . Table indicates whether a correct relationship exists between system operating pressure and air temperature entering indoor and outdoor units . If pressure and temperature do not match on chart , system refrigerant charge may not be correct or other system abnormalities may exist . Do not use table to adjust refrigerant charge . When charging is necessary during heating season , weigh in total charge as indicated on unit rating plate . Rating plate charge is for systems with 15 ft . line - set . Adjust charge at rate of 0.6 oz / ft of 3 / 8 " liquid line above or below 15 ft . Remove any refrigerant remaining in system before recharging . If the system has lost complete charge , evacuate and recharge by weight . 327634 - 101 REV . A A02019 Fig . 1 — PH10JA018 – 060 Form : HC - PH10 - 05 Cancels : HC - PH10 - 04 Printed in U.S.A . 3 - 02 Catalog No . 53PH - 1019 Page: 2 © 2002 Payne Heating & Cooling 7310 W . Morris St . , Indianapolis , IN 46231 — 2 — hcph1004 Catalog No . 53PH - 1019 |