Back To Payne Heat Pump       Model: PH12 Payne Wiring Diagrams Information for PH10 PH12 Series Heat Pump
Regular Text Search or Search by Model Number

Register / log-in to add to your Hammerwall Collection.
Manual Location


This is a partial text extraction from the pdf, to download the pdf, click the Manual tab. If you want to search this text, hold control and F, and type the word you are looking for.

Page: 1

Wiring Diagrams Heat Pump 1PH102 PH UNIT - SIZE SERIES DIAGRAM NUMBER VOLTS FIGURE NUMBER PAGE NUMBER PH10JA - 018 - 036 D - F 327418 - 101 208 / 230 - 1 - 60 1 2 PH10JA - 042 B , C 327418 - 101 208 / 230 - 1 - 60 1 2 PH10JA - 048 B 327418 - 101 208 / 230 - 1 - 60 1 2 PH10PA - 048 - 060 C 327414 - 101 208 / 230 - 3 - 60 2 3 PH12NA - 018 - 048 B - D 327418 - 101 208 / 230 - 1 - 60 1 2 PH12NA - 060 B , C 327417 - 101 208 / 230 - 1 - 60 3 4 Form : WD - PH10 - 06 Cancels : New Printed in U.S.A . 5 - 05 Catalog No . WD - PH10 - 06
Page: 2

SCHEMATIC DIAGRAM ( LADDER FORM ) CONNECTION DIAGRAM * CHS * CH BLK BLK * CH or BLK * CHS RED CAP L1 COMP BLU BLK BLU S C RED or BLK H CONT R COMP CONT + t ° L1 BLK C YEL L2 C R 230 1Ø * ST 11 21 L2 11 21 YEL S EQUIP POWER 23 23 YEL * ST F GND SUPPLY + t ° EQUIP GND BRN H BLK CONT OFM YEL C DR BLK 23 23 OFM YEL F CAP OF1 OF2 BRN YEL orBLU * LPS RVS YEL BLU C * HPS YEL DR O O Y W2 DFT R R DFT DR T1 YEL LOGIC OF1 C BRN DR C ORG T1 LOGCI Y Y RVS C OF2 O ORG ORG ORG 50 SPEED or or * * UP 90 CONT BLK BLK * HPS * LPS * DTS C 30 DFT PNK PNK CY O W2 R R BLK BLK CB 90 or or FIELD SELECTED TIME PERIOD HK32EA001 WHT YEL 50 PNK PNK * * BETWEEN DEFROST CYCLES ( MINUTES ) 30 RED DFT BLK ORN SPEED JUMPERED TEST PINS ( USE METAL OBJECT ) , FIELD SPEED - UP CYCLE UP HEAT CYCLE : 90 MIN . ACCELERATED TO 21 SEC . INDOOR UNIT C Y O W2 R E L W3 G . * * BOARD MAY HAVE 60 60 MIN . ACCELERATED TO 14 SEC . TERMINAL BLOCK AS MIDDLE SELECTION * * . 50 MIN . ACCELERATED TO 12 SEC . 30 MIN . ACCELERATED TO 7 SEC . C Y O W2 R E L G INDOOR THERMOSTAT ( NOTE # 5 ) DEFROST CYCLE : 10 MIN . ACCELERATED TO 2 SEC . - LEGEND - NOTES : FACTORY POWER WIRING 1 . COMPRESSOR AND FAN MOTOR FURNISHED WITH INHERENT FIELD POWER WIRING FACTORY CONTROL WIRING THERMAL PROTECTION . FIELD CONTROL WIRING 2 . TO BE WIRED IN ACCORDANCE WITH NATIONAL ELECTRIC CODE CONDUCTOR ON CIRCUIT BOARD ( N.E.C . ) AND LOCAL CODES . COMPONENT CONNECTION 3 . N.E.C . CLASS 2 , 24 V CIRCUIT , MIN . 40 VA REQUIRED . 1 / 4 - INCH QUICK CONNECT TERMINALS 4 . USE COPPER CONDUCTORS ONLY FROM DISCONNECT TO UNIT . FIELD SPLICE JUNCTION 5 . MUST USE THERMOSTAT AND SUB - BASE AS STATED IN PRE - SALE CAPACITOR ( DUAL RUN ) CAP LITERATURE . CRANKCASE HEATER * CH 6 . IF INDOOR SECTION HAS A TRANSFORMER WITH A GROUNDED CRANKCASE HEATER SWITCH * CHS SECONDARY , CONNECT THE GROUNDED SIDE TO " C " ON THE COMPRESSOR COMP CIRCUIT BOARD . CONTACTOR CONT CIRCUIT BOARD CB 7 . IF ANY OF THE ORIGINAL WIRE , AS SUPPLIED , MUST BE REPLACED , DEFROST THERMOSTAT DFT USE THE SAME OR EQUIVALENT WIRE . DEFROST RELAY AND CIRCUITRY DR 8 . CHECK ALL ELECTRICAL CONNECTIONS INSIDE CONTROL BOX DISCHARGE TEMP . SWITCH * DTS FOR TIGHTNESS . HIGH PRESSURE SWITCH * HPS 9 . DO NOT ATTEMPT TO OPERATE UNIT UNTIL SERVICE VALVES LOW PRESSURE SWITCH * LPS OUTDOOR FAN MOTOR OFM HAVE BEEN OPENED . REVERSING VALVE SOLENOID RVS 10 . USE CONDUCTORS SUITABLE FOR AT LEAST 75ºC ( 167ºF ) . START CAPACITOR * SC START RELAY * SR START THERMISTOR * ST 327418 - 101 REV . B * MAY BE FACTORY OR FIELD INSTALLED . A05023 Fig . 1 — Label Wiring 327418 - 101 — 2 —
Page: 3

SCHEMATIC DIAGRAM ( LADDER FORM ) CONNECTION DIAGRAM L2 BLU L2 L3 COMP T2 PRM 208 / 230 3Ø L1 L2 BLU BLK T3 CONT T1 L1 L1 L3 POWER CAP 21 YEL 11 SUPPLY L3 YEL ALERT ! 23 13 COMP CONT T2 RED or BLK ( NOTE # 11 ) * CH EQUIP GND T3 RED T1 or 21 BLK 11 EQUIP BRN NBLK GND YEL R CAP BOFM YEL YEL PRM DR OFM CONT L2 L1 L3 N YEL or RBLU OF1 OF2 23 B13 CONT 24V COM * CH RVS C YEL or BLU BLK GRY * LPS * DTS * HPS O O BLK BLU YEL PRM BLK YEL W2 24V COM CONT R R DFT DFT BLK LOGIC Y BLK DR Y Y DR T1 T1 YEL OF1 C BRN ORG * HPS C C * DTS * LPS C CONT LOGIC RVS OF2 O ORG 90 ORG ORG FIELD SELECTED TIME DPERIOD 50 50 or or E * * P * * BETWEEN DEFROST CYCLES E ( MINUTES ) 90 BLK 30 BLK U P S 30 DFT SPEED JUMPERED TEST PINS ( USE METAL OBJECT ) , FIELD SPEED - UP CYCLE PNK UP PNK C Y OW2R DFT R HEAT CYCLE : 90 MIN . ACCELERATED TO 21 SEC . NOTE BLK BLK CB or HK32EA001 or 60 MIN . ACCELERATED TO 14 SEC . PRM LED INDICATOR WHT YEL * * PNK PNK 50 MIN . ACCELERATED TO 12 SEC . OFF : NO 24VAC RED BLK ORN 30 MIN . ACCELERATED TO 7 SEC . * * BOARD MAY HAVE 60 ON : OK DEFROST CYCLE : AS MIDDLE SELECTION 10 MIN . ACCELERATED TO 2 SEC . FLASH : PHASE PROBLEM INDOOR UNIT C Y O W2 R E L W3 G TABLE I - SUPERHEAT CHARGING TABLE COOLING ONLY TERMINAL BLOCK ( SUPERHEAT ºF AT LOW - SIDE SERVICE PORT ) PROCEDURE EVAPORATOR ENTERING AIR ºF WB . OUTDOOR C Y O W2 R E L G INDOOR THERMOSTAT ( NOTE # 5 ) 1 . Operate unit a minimum of 50 52 54 56 58 60 62 64 66 68 70 72 74 76 TEMP ° F 10 minutes before checking 14 35 32 40 45 23 12 20 29 26 55 9 37 17 42 NOTES : charge . - LEGEND - 60 7 43 38 40 23 27 12 15 30 33 18 23 10 35 1 . Compressor and fan motor furnished with 2 . Measure suction pressure inherent thermal protection . FACTORY POWER WIRING 24 41 38 65 - - 6 13 19 30 33 36 10 16 21 27 by attaching a gage to 2 . To be wired in accordance with National suction valve service port . 13 19 10 16 21 70 - - - - 7 39 33 36 24 27 30 FIELD POWER WIRING Electric Code ( N.E.C . ) and local codes . 3 . Measure suction temperature 75 - - - - - - 6 9 12 15 18 21 24 28 31 34 37 3 . N.E.C . class 2 , 24V circuit , min . 40 VA required . FACTORY CONTROL WIRING by attaching an accurate 4 . Use copper conductors only , from disconnect 80 - - - - - - - - 5 8 12 15 18 21 25 28 31 35 thermistor type or electronic to unit . FIELD CONTROL WIRING 33 85 - - - - - - - - - - - - 8 11 15 19 22 26 30 thermometer to the suction 5 . Must use thermostat and sub - base as stated line at service valve . CONDUCTOR ON CIRCUIT 5 9 13 16 20 24 27 31 90 - - - - - - - - - - - - in pre - sale literature . 4 . Measure outdoor air dry - bulb 6 . If indoor section has a transformer with a 18 10 22 25 14 29 95 6 - - - - - - - - - - - - - - BOARD temperature with a grounded secondary , connect the grounded 100 - - 8 12 15 20 23 27 - - - - - - - - - - - - - - thermometer . side to " C " on the circuit board . COMPONENT CONNECTION 5 . Measure indoor air ( entering - - - - - - - - - - - - 105 - - - - 5 9 13 17 22 26 7 . If any of the original wire , as supplied , must indoor coil ) wet bulb 1 / 4 - INCH QUICK CONNECT 20 25 11 15 be replaced , use the same or equivalent wire . - - - - - - - - - - - - 110 - - - - - - 6 temperature with a sling 8 . Check all electrical connections inside control 23 115 - - - - - - - - 8 - - - - - - - - - - - - 18 14 TERMINALS psychrometer . box for tightness . 6 . Refer to table I . Find out - 9 . Do not attempt to operate unit until service FIELD SPLICE TABLE II - REQUIRED SUCTION TUBE TEMPERATURE ºF door temperature and valves have been opened . ( MEASURED AT LOW - SIDE SERVICE PORT ) JUNCTION evaporator entering air wet - 10 . It is imperative to connect 3Ø field power bulb temperature at this SUPERHEAT SUCTION PRESSUR E AT SERVICE PORT PSIG . to unit with correct phasing . The Phase CAPACITOR ( DUAL RUN ) CAP intersection note the super - Rotation Monitor will not allow the contactor TEMP . ° F 61.5 64.2 67.1 70.0 73.0 76.0 79.2 82.4 85.7 heat . to be energized if thephasing is not correct . CRANKCASE HEATER * CH 35 37 39 41 43 45 47 49 51 0 7 . Refer to table II . Find super - If phasing is reversed , simply interchange any two 37 39 41 43 45 47 49 51 53 2 COMPRESSOR COMP of the three power connections on the field side . heat temperature located in 39 41 43 45 47 49 51 53 55 4 11 . Use conductors suitable for at least 75ºC ( 167ºF ) . step 6 and suction pressure , CONTACTOR CONT 41 43 45 47 49 51 53 55 57 6 at this intersection note 43 45 47 49 51 53 55 57 59 CAUTION 8 CIRCUIT BOARD CB suction line temperature . 45 47 49 51 53 55 57 59 61 10 8 . If unit has a higher suction 1 . Compressor damage may occur if system is over DEFROST THERMOSTAT DFT 47 49 51 53 55 57 59 61 63 12 line temperature than charted charged.t 49 51 53 55 57 59 61 63 65 14 temperature , add refrigerant 2 . This uni is factory charged with R - 22 in accordance DEFROST RELAY AND DR with the amount shown on the rating plate . The until charted temperature 51 53 55 57 59 61 63 65 67 16 CIRCUITRY charge is adequate for most systems usingt is reached . 53 55 57 59 61 63 65 67 69 18 matched coils and tubing not over 15 fee ilong.hehetions 9 . If unit has a lower suction 55 57 59 61 63 65 67 69 71 20 DISCHARGE TEMP . SWITCH * DTS The best performance will be achieved when ettdute line temperature than charted 57 59 61 63 65 67 69 71 73 22 unit operates with a suction gas superheat tatnitat HIGH PRESSURE SWITCH temperature , remove and * HPS 59 61 63 65 67 69 71 73 75 24 compressor inlet of 5 ºF at normal rating cosim recover refrigerant until 61 63 65 67 69 71 73 75 77 26 LOW PRESSURE SWITCH * LPS of the air conditioning and refrigeration , inx charted temperature is 63 65 67 69 71 73 75 77 79 28 ( ARI ) . This chart may be used to appro ethed.A " reached . OUTDOOR FAN MOTOR OFM 65 67 69 71 73 75 77 79 81 charge if ARI rating conditions cannot be eobtainst 30 10 . If outdoor air temperature ARI rating conditions are equivalent to DOE t vr " eder 67 69 71 73 75 77 79 81 83 32 PHASE ROTATION MONITOR PRM or pressure at suction valve conditions . See product data literature for requi 69 71 73 75 77 79 81 83 85 34 changes , charge to new REVERSING VALVE RVS indoor air flow rates and for use of line lengths o 71 73 75 77 79 81 83 85 87 suction line temperature 36 15 Ft.ve indicated on chart . SOLENOID 73 75 77 79 81 83 85 87 89 38 3 . Relie pressure and recover all refrigerant beforeice 11 . This procedure is valid when 75 77 79 81 83 85 87 89 91 40 system repair or final unit disposal . Use all servng indoor air flow is within ports and open all flow - control devices , includi + / - 21 % of its rated cfm . * MAY BE FACTORY OR FIELD INSTALLED . 327414 - 101 REV . B solenoid valves . A05019 Fig . 2 — Label Wiring 327414 - 101 — 3 —
Page: 4

SCHEMATIC DIAGRAM ( LADDER FORM ) CONNECTION DIAGRAM * CHS * CH * CH BLK L1 or BLK BLK * CHS CAP COMP COMP RED BLU BLU S BLK R L2 CONT C H C RED or BLK CONT + t ° BLK L1 YEL C 21 R 11 S * ST 208 / 230 1Ø 11 21 L2 * ST YEL POWER F + t ° 23 13 YEL EQUIP SUPPLY H BRN GND EQUIP GND CONT BLK OFM C OFM DR 23 13 BLK YEL F CAP OF2 OF1 BRN YEL * HPS * LPS YEL YEL or BLU BLU RVS YEL C DR O O Y W2 DR DFT T1 YEL R R DFT OF1 C LOGIC BRN DR C ORG LOGCI T1 RVS OF2 O ORG Y ORG Y ORG SPEED C 50 or or * * UP 90 BLK BLK 30 DFT CONT * HPS * LPS * DTS PNK C PNK C Y OW2R R BLK BLK CB or or HK32EA001 WHT YEL PNK PNK 90 FIELD SELECTED TIME PERIOD RED DFT BLK ORN 50 * * BETWEEN DEFROST CYCLES ( MINUTES ) 30 SPEED JUMPERED TEST PINS ( USE METAL OBJECT ) , FIELD SPEED - UP CYCLE INDOOR UNIT C Y O W2 R E L W3 G UP BOARD MAY HAVE 60 * * HEAT CYCLE : TERMINAL BLOCK 90 MIN . ACCELERATED TO 21 SEC . AS MIDDLE SELECTION 60 MIN . ACCELERATED TO 14 SEC . * * C Y O W2 R E L G INDOOR THERMOSTAT ( NOTE # 5 ) 50 MIN . ACCELERATED TO 12 SEC . 30 MIN . ACCELERATED TO 7 SEC . DEFROST CYCLE : 10 MIN . ACCELERATED TO 2 SEC . - LEGEND - NOTES : FACTORY POWER WIRING 1 . COMPRESSOR AND FAN MOTOR FURNISHED WITH INHERENT FIELD POWER WIRING FACTORY CONTROL WIRING THERMAL PROTECTION . FIELD CONTROL WIRING 2 . TO BE WIRED IN ACCORDANCE WITH NATIONAL ELECTRIC CODE CONDUCTOR ON CIRCUIT BOARD ( N.E.C . ) AND LOCAL CODES . COMPONENT CONNECTION 3 . N.E.C . CLASS 2 , 24 V CIRCUIT , MIN . 40 VA REQUIRED . 1 / 4 - INCH QUICK CONNECT TERMINALS 4 . USE COPPER CONDUCTORS ONLY FROM DISCONNECT TO UNIT . FIELD SPLICE JUNCTION 5 . MUST USE THERMOSTAT AND SUB - BASE AS STATED IN PRE - SALE CAPACITOR ( DUAL RUN ) CAP LITERATURE . CRANKCASE HEATER * CH 6 . IF INDOOR SECTION HAS A TRANSFORMER WITH A GROUNDED CRANKCASE HEATER SWITCH * CHS SECONDARY , CONNECT THE GROUNDED SIDE TO " C " ON THE COMPRESSOR COMP CIRCUIT BOARD . CONTACTOR CONT CIRCUIT BOARD CB 7 . IF ANY OF THE ORIGINAL WIRE , AS SUPPLIED , MUST BE REPLACED , DEFROST THERMOSTAT DFT USE THE SAME OR EQUIVALENT WIRE . DEFROST RELAY AND CIRCUITRY DR 8 . CHECK ALL ELECTRICAL CONNECTIONS INSIDE CONTROL BOX DISCHARGE TEMP . SWITCH * DTS FOR TIGHTNESS . HIGH PRESSURE SWITCH * HPS 9 . DO NOT ATTEMPT TO OPERATE UNIT UNTIL SERVICE VALVES LOW PRESSURE SWITCH * LPS OUTDOOR FAN MOTOR OFM HAVE BEEN OPENED . REVERSING VALVE SOLENOID RVS 10 . USE CONDUCTORS SUITABLE FOR AT LEAST 75ºC ( 167ºF ) . START CAPACITOR * SC START RELAY * SR START THERMISTOR * ST 327417 - 101 REV . B * MAY BE FACTORY OR FIELD INSTALLED . A05022 Fig . 3 — Label Wiring 327417 - 101 © 2005 Payne Heating & Cooling 7310 W . Morris St . , Indianapolis , IN 46231 — 4 — Catalog No . WD - PH10 - 06