TOC MotorPal DEWALT 7 / 13 / 05 3 : 03 PM Page vii Chapter 1 – Formulas and Fundamentals . . . . . . . . . 1 - 1 Inductance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 - 2 Capacitance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 - 4 Mechanical and Electrical Degrees . . . . . . . . . . . . . . . . . . 1 - 5 Poles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 - 6 Synchronous Speed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 - 7 Slip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 - 7 Speed Regulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 - 7 AC Motor Torque . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 - 8 Wound - Rotor Motor Torque . . . . . . . . . . . . . . . . . . . . . . . . 1 - 9 DC Motor Torque . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 - 10 Squirrel - Cage Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 - 11 Wound - Rotor Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 - 12 Synchronous Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 - 13 DC Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 - 14 Ohm’s Law for Alternating Current . . . . . . . . . . . . . . . . . 1 - 15 Ohm’s Law for Direct Current . . . . . . . . . . . . . . . . . . . . . 1 - 16 Power Factor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 - 16 Single - Phase Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 - 16 Three - Phase AC Circuits and the Utilization of Power . . . . . . . . . . . . . . . . . . . . . . . . 1 - 17 Wye Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 - 17 Delta Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 - 17 Four - Wire System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 - 17 Types of Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 - 18 True Power and Apparent Power . . . . . . . . . . . . . . . . . . 1 - 19 vii
Page: 2

TOC MotorPal DEWALT 7 / 13 / 05 3 : 03 PM Page viii Power Factor Formula . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 - 19 AC / DC Power Formulas . . . . . . . . . . . . . . . . . . . . . . . . . . 1 - 20 Horsepower Formulas . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 - 21 Efficiency Formulas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 - 21 Voltage Unbalance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 - 21 Temperature Conversions . . . . . . . . . . . . . . . . . . . . . . . . 1 - 21 Voltage Drop Formulas . . . . . . . . . . . . . . . . . . . . . . . . . . 1 - 22 Conductor Length / Voltage Drop . . . . . . . . . . . . . . . . . . . 1 - 22 Conductor Size / Voltage Drop . . . . . . . . . . . . . . . . . . . . . 1 - 22 Formulas for Sine Waves . . . . . . . . . . . . . . . . . . . . . . . . . 1 - 23 Calculating Root - Mean - Square ( RMS ) . . . . . . . . . . . . . . 1 - 23 Summary of Series , Parallel and Combination Circuits . . . . . . . . . . . . . . . . . . . . . . . . . . 1 - 24 Chapter 2 – Motor Construction . . . . . . 2 - 1 Capacitor - Start Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 - 1 Operation of Capacitor - Start Motor . . . . . . . . . . . . . . . . . 2 - 2 Four - Pole Capacitor - Start Motor . . . . . . . . . . . . . . . . . . . . 2 - 3 Four - Pole , Two - Circuit Capacitor - Start Motor . . . . . . . . . 2 - 4 Six - Pole Capacitor - Start Motor . . . . . . . . . . . . . . . . . . . . . 2 - 5 Dual - Voltage Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 - 6 Single - Voltage Capacitor - Start Motor . . . . . . . . . . . . . . . . 2 - 8 Dual - Voltage Capacitor - Start Motor . . . . . . . . . . . . . . . . . 2 - 9 Reversing Single - Phase Motors . . . . . . . . . . . . . . . . . . . 2 - 11 Jumpers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 - 12 Six - Pole Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 - 15 Reversing Split - Phase Motors . . . . . . . . . . . . . . . . . . . . . 2 - 16 viii
Page: 3

TOC MotorPal DEWALT 7 / 13 / 05 3 : 03 PM Page ix Permanent - Split Capacitor Motor . . . . . . . . . . . . . . . . . . 2 - 17 Two - Value Capacitor Motor . . . . . . . . . . . . . . . . . . . . . . . 2 - 18 Synchronous Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 - 19 Shaded - Pole Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 - 22 Capacitor Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 - 27 Multi - Speed Single - Phase Motors . . . . . . . . . . . . . . . . . 2 - 29 Universal Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 - 34 Connections for Multi - Speed Squirrel - Cage Motors . . . 2 - 39 Wye Three - Phase Motors . . . . . . . . . . . . . . . . . . . . . . . . 2 - 44 Reversing Direction . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 - 45 Standard Markings . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 - 46 Series - Star . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 - 48 Four - Pole . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 - 50 Wye - Wound Motor for Use on 240 / 480 Volts . . . . . . . . . 2 - 52 Numbering of Dual - Voltage Wye - Wound Motor . . . . . . . 2 - 52 Delta Three - Phase Motors . . . . . . . . . . . . . . . . . . . . . . . . 2 - 53 Standard Markings . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 - 53 Four - Pole Series Delta . . . . . . . . . . . . . . . . . . . . . . . . . 2 - 55 DC Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 - 56 Two - Pole Compound - Interpole . . . . . . . . . . . . . . . . . . 2 - 56 Brush Positions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 - 58 Two - Pole Shunt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 - 61 Two - Pole Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 - 63 Compound - Interpole . . . . . . . . . . . . . . . . . . . . . . . . . . 2 - 65 Cumulative Compound . . . . . . . . . . . . . . . . . . . . . . . . 2 - 69 ix
Page: 4

TOC MotorPal DEWALT 7 / 13 / 05 3 : 03 PM Page x Chapter 3 – Connections and Diagrams . . . . . . . . . . 3 - 1 Delta - Wound Motor for Use on 240 / 480 Volts . . . . . . . . . 3 - 1 Wye - Wound Motor for Use on 240 / 480 Volts . . . . . . . . . . 3 - 1 Split - Phase Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 - 2 Split - Phase Motor Rotation . . . . . . . . . . . . . . . . . . . . . . . . 3 - 3 3φ Single - Voltage , , Wye - Connected Motor . . . . . . . . . . . 3 - 4 3φ Single - Voltage , , Delta - Connected Motor . . . . . . . . . . . 3 - 4 3φ Dual - Voltage , , Wye - Connected Motors . . . . . . . . . . . . 3 - 5 Two - Phase , AC Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 - 6 Connections for A Two - Speed , Constant Horsepower , One Winding Motor . . . . . . . . . 3 - 7 Connections for A Two - Speed , Constant Torque , One Winding Motor . . . . . . . . . . . . . . 3 - 8 Connections for A Two - Speed , Variable Torque , One Winding Motor . . . . . . . . . . . . . . . 3 - 9 Capacitor - Start - Capacitor - Run Motor . . . . . . . . . . . . . . . 3 - 10 Reversing A Capacitor - Start Motor . . . . . . . . . . . . . . . . . 3 - 10 Capacitor - Start Motor Voltage Connections . . . . . . . . . . 3 - 11 Two - Speed Capacitor Motor . . . . . . . . . . . . . . . . . . . . . . 3 - 11 Wound - Rotor Motor Schematic . . . . . . . . . . . . . . . . . . . 3 - 12 Reversing Split - Phase Motors . . . . . . . . . . . . . . . . . . . . . 3 - 12 Typical Motor Starter Diagram . . . . . . . . . . . . . . . . . . . . . 3 - 13 Step - Down Transformer Motor Control . . . . . . . . . . . . . 3 - 13 Motor Control Circuits . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 - 14 Stop - Start Stations , Jogging , Plugging . . . . . . . . . . . . 3 - 15 Low - Voltage Control , Magnetic Starters . . . . . . . . . . . 3 - 17 x
Page: 5

TOC MotorPal DEWALT 7 / 13 / 05 3 : 03 PM Page xi Magnetic Starters , Starting Compensator . . . . . . . . . 3 - 19 Reversing Type Starter . . . . . . . . . . . . . . . . . . . . . . . . . 3 - 21 Two - Speed Motor with Push - Button . . . . . . . . . . . . . . 3 - 23 Manual Type Starting Compensator . . . . . . . . . . . . . . 3 - 25 Resistance and Faceplate Starters . . . . . . . . . . . . . . . 3 - 27 Regulating Rheostat . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 - 29 Adjustable - Speed Capacitor Motors . . . . . . . . . . . . . . 3 - 31 Multi - Speed Motor Control . . . . . . . . . . . . . . . . . . . . . 3 - 33 Synchronous Motors , Exciter - Field Rheostat . . . . . . . 3 - 38 Reduced - Voltage Starting Systems . . . . . . . . . . . . . . 3 - 44 Changing Speeds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 - 47 Starting , Stopping , Jogging . . . . . . . . . . . . . . . . . . . . . 3 - 53 DC Series - Wound Motor . . . . . . . . . . . . . . . . . . . . . . . . . 3 - 54 DC Shunt - Wound Motor . . . . . . . . . . . . . . . . . . . . . . . . . 3 - 54 DC Compound - Wound Motor . . . . . . . . . . . . . . . . . . . . . 3 - 54 DC Motor Connections . . . . . . . . . . . . . . . . . . . . . . . . . . 3 - 55 Series - Wound . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 - 55 Shunt - Wound , Compound - Wound . . . . . . . . . . . . . . . 3 - 57 Compound Generators . . . . . . . . . . . . . . . . . . . . . . . . 3 - 61 Commutating - Pole . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 - 63 DC Motor Control Circuits . . . . . . . . . . . . . . . . . . . . . . . . 3 - 64 Variable Resistance Speed Control . . . . . . . . . . . . . . . 3 - 65 Speed - Regulating Faceplate Starter . . . . . . . . . . . . . . 3 - 69 Speed - Regulating Rheostat Control . . . . . . . . . . . . . . 3 - 71 Step - by - Step Resistance Regulation . . . . . . . . . . . . . 3 - 73 Constant - Speed Shunt and Compound - Wound Reversible Motor Control . . . . . . . . . . . . . . . . . . . . . . . 3 - 75 xi
Page: 6

TOC MotorPal DEWALT 7 / 13 / 05 3 : 03 PM Page xii Chapter 4 – Design and Installation . . . 4 - 1 Designing Motor Circuits . . . . . . . . . . . . . . . . . . . . . . . . . . 4 - 2 Tips on Selecting Motors . . . . . . . . . . . . . . . . . . . . . . . . . . 4 - 3 Facts to Consider . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 - 3 Summary of Motor Applications . . . . . . . . . . . . . . . . . . . . 4 - 4 Three - Phase Motor Requirements . . . . . . . . . . . . . . . . . . 4 - 8 Direct Current Motor Requirements . . . . . . . . . . . . . . . . . 4 - 9 1φ 115 V Motors and Circuits – 120 V System . . . . . . . . 4 - 10 1φ 230 V Motors and Circuits – 240 V System . . . . . . . . 4 - 11 3φ 230 V Motors and Circuits – 240 V System . . . . . . . . 4 - 13 3φ 460 V Motors and Circuits – 480 V System . . . . . . . . 4 - 16 DC Motors and Circuits . . . . . . . . . . . . . . . . . . . . . . . . . . 4 - 19 Control Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 - 22 Standard Motor Sizes . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 - 25 Starting Methods : Squirrel - Cage Induction Motors . . . . 4 - 26 Setting Branch Circuit Protective Devices . . . . . . . . . . . 4 - 27 Maximum OCPD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 - 28 Standard Sizes of Fuses and CB’s . . . . . . . . . . . . . . . . . 4 - 28 Motor Power Formulas — Cost Savings . . . . . . . . . . . . 4 - 29 Heater Selections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 - 30 Heater Trip Characteristics . . . . . . . . . . . . . . . . . . . . . . . 4 - 33 Heater Ambient Temperature Correction . . . . . . . . . . . . 4 - 34 Heating Element Specifications . . . . . . . . . . . . . . . . . . . . 4 - 35 Heater Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 - 36 Motor Bearings and End Plates . . . . . . . . . . . . . . . . . . . 4 - 37 Motor Disconnects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 - 38 Motor Feeder Tap Sizing . . . . . . . . . . . . . . . . . . . . . . . . . 4 - 40 xii
Page: 7

TOC MotorPal DEWALT 7 / 13 / 05 3 : 03 PM Page xiii General Controller Fault Current Limits . . . . . . . . . . . . . . 4 - 41 Horsepower Limits of Individual Motors . . . . . . . . . . . . . 4 - 41 Common Service Factors . . . . . . . . . . . . . . . . . . . . . . . . 4 - 42 Small Motor Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 - 43 DC Motor Performance Characteristics . . . . . . . . . . . . . 4 - 44 Maximum Acceleration Time . . . . . . . . . . . . . . . . . . . . . . 4 - 44 DC Motor Efficiencies , Continuous Rated , 40 ° C Rise . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 - 45 Power Factor Improvement . . . . . . . . . . . . . . . . . . . . . . . 4 - 46 Typical Motor Power Factors . . . . . . . . . . . . . . . . . . . . . . 4 - 47 Efficiency Formulas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 - 47 Voltage Unbalance Formula . . . . . . . . . . . . . . . . . . . . . . . 4 - 47 Motor Torque ( Inch Pounds - Force ) . . . . . . . . . . . . . . . . . 4 - 48 Horsepower to Torque Conversion . . . . . . . . . . . . . . . . . 4 - 51 Locked Rotor Current . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 - 52 Nema Ratings of 60Hz AC Contactors . . . . . . . . . . . . . . 4 - 53 Full - Load Currents : DC Motors . . . . . . . . . . . . . . . . . . . . 4 - 54 1φ Full - Load Currents : , AC Motors . . . . . . . . . . . . . . . . . 4 - 54 3φ Full - Load Currents : , AC Induction Motors . . . . . . . . . 4 - 55 General Effect of Voltage Variation on Direct Currect Motor Characteristics . . . . . . . . . . . . . . 4 - 56 General Effect of Voltage and Frequency Variation on Induction Motor Characteristics . . . . . . . 4 - 57 Voltage Variation Characteristics . . . . . . . . . . . . . . . . . . . 4 - 58 Frequency Variation Characteristics . . . . . . . . . . . . . . . . 4 - 58 Typical Motor Efficiencies . . . . . . . . . . . . . . . . . . . . . . . . 4 - 59 Types of Enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 - 60 xiii
Page: 8

TOC MotorPal DEWALT 7 / 13 / 05 3 : 03 PM Page xiv Enclosure Insulation , Temperature . . . . . . . . . . . . . . . . . 4 - 60 Enclosure Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 - 61 Hazardous Locations . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 - 61 Enclosure Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 - 62 Frontal View of Typical Motor . . . . . . . . . . . . . . . . . . . . . 4 - 64 Side View of Typical Motor . . . . . . . . . . . . . . . . . . . . . . . 4 - 64 NEMA Motor Frame Dimensions . . . . . . . . . . . . . . . . . . . 4 - 65 Shaft Coupling Selections . . . . . . . . . . . . . . . . . . . . . . . . 4 - 66 Motor Frame Letters . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 - 67 Motor Frame Dimensions . . . . . . . . . . . . . . . . . . . . . . . . 4 - 68 Motor Frame Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 - 70 Motor and Ampacity Ratings . . . . . . . . . . . . . . . . . . . . . . 4 - 72 Locations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 - 72 Grounding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 - 72 Overload Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 - 72 Motor Circuit Conductors . . . . . . . . . . . . . . . . . . . . . . . . 4 - 75 Motor Controllers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 - 76 Motor Control Circuits . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 - 77 Conductors Supplying Motors and Other Loads . . . . . . 4 - 78 Conductors Supplying Several Motors . . . . . . . . . . . . . . 4 - 79 Short - Circuit and Ground - Fault Protection . . . . . . . . . . . 4 - 79 Adjustable - Speed Drives . . . . . . . . . . . . . . . . . . . . . . . . . 4 - 80 Chapter 5 – Maintenance . . . . . . . . . . . . 5 - 1 Motor Maintenance Operations . . . . . . . . . . . . . . . . . . . . . 5 - 2 Motor Repair and Service Record . . . . . . . . . . . . . . . . . . . 5 - 4 Semiannual Motor Maintenance Checklist . . . . . . . . . . . . 5 - 5 xiv
Page: 9

TOC MotorPal DEWALT 7 / 13 / 05 3 : 03 PM Page xv Annual Motor Maintenance Checklist . . . . . . . . . . . . . . . . 5 - 6 Locating Circuits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 - 8 Checking Capacitors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 - 9 3φ Unmarked Induction Motors . . . . . . . . . . . . . . . . . . . . 5 - 10 Wye Or Delta Connection . . . . . . . . . . . . . . . . . . . . . . . . 5 - 10 Wye - Connected Motor . . . . . . . . . . . . . . . . . . . . . . . . . . 5 - 11 Delta - Connected Motor . . . . . . . . . . . . . . . . . . . . . . . . . . 5 - 11 DC Motor Performance Characteristics . . . . . . . . . . . . . 5 - 12 Maximum Acceleration Time . . . . . . . . . . . . . . . . . . . . . . 5 - 12 AC Voltage Variation Characteristics . . . . . . . . . . . . . . . . 5 - 13 AC Frequency Variation Characteristics . . . . . . . . . . . . . 5 - 13 Phase Unbalance and Temperature Rise . . . . . . . . . . . . 5 - 14 Phase Unbalance Derating Factor . . . . . . . . . . . . . . . . . 5 - 15 Single - Phasing Condition . . . . . . . . . . . . . . . . . . . . . . . . 5 - 16 Improper Phase Sequence ( Phase Reversal ) . . . . . . . . . 5 - 17 Voltage Surge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 - 17 Voltage Problems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 - 18 Voltage Variance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 - 19 Acceptable AC Load Voltage Ranges ( 60Hz ) . . . . . . . . . 5 - 19 Voltage Unbalance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 - 20 Finding Voltage Unbalance . . . . . . . . . . . . . . . . . . . . . . . 5 - 21 Motor Overcycling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 - 22 Improper Ventilation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 - 22 Excessive Heat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 - 23 Motor Overloads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 - 24 Megohmmeter Connections . . . . . . . . . . . . . . . . . . . . . . 5 - 25 Ohmmeter Connections . . . . . . . . . . . . . . . . . . . . . . . . . . 5 - 26 xv
Page: 10

TOC MotorPal DEWALT 7 / 13 / 05 3 : 03 PM Page xvi Insulation Spot Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 - 27 Dielectric Absorption Testing . . . . . . . . . . . . . . . . . . . . . . 5 - 28 Polarization Index Values . . . . . . . . . . . . . . . . . . . . . . . . . 5 - 29 Insulation Step Voltage Testing . . . . . . . . . . . . . . . . . . . . 5 - 30 Chapter 6 – Troubleshooting . . . . . . . . . 6 - 1 Contactor and Motor Starter Troubleshooting Guide . . . . 6 - 2 Direct Current Motor Troubleshooting Guide . . . . . . . . . . 6 - 4 Shaded Pole Motor Troubleshooting Guide . . . . . . . . . . . 6 - 6 Split - Phase Motor Troubleshooting Guide . . . . . . . . . . . . 6 - 7 Three - Phase Motor Troubleshooting Guide . . . . . . . . . . 6 - 10 Faulty Solenoid Problems . . . . . . . . . . . . . . . . . . . . . . . . 6 - 12 Mechanical Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 - 14 Split - Phase Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 - 14 Motor Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 - 15 Defective Pole . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 - 16 Start Winding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 - 17 Stator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 - 18 Grounded Winding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 - 19 Disassembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 - 19 Shorted Coil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 - 20 Opens . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 - 22 Interpole Polarity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 - 24 Brushes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 - 25 Compound Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 - 26 DC Opens . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 - 30 DC Grounds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 - 33 xvi
Page: 11

TOC MotorPal DEWALT 7 / 13 / 05 3 : 03 PM Page xvii Two - Pole Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 - 36 Polarity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 - 38 AC Grounds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 - 41 AC Opens . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 - 45 Shorts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 - 52 Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 - 53 Mechanical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 - 55 Chapter 7 – Power Transmission . . . . . 7 - 1 Method of Aligning Pulleys . . . . . . . . . . . . . . . . . . . . . . . . 7 - 1 Calculating Pulley Diameter . . . . . . . . . . . . . . . . . . . . . . . . 7 - 2 Pulley and Gear Calculations . . . . . . . . . . . . . . . . . . . . . . . 7 - 3 Formulas for Finding Pulley Sizes . . . . . . . . . . . . . . . . . . . 7 - 4 Formulas for Finding Gear Sizes . . . . . . . . . . . . . . . . . . . . 7 - 4 Formula to Determine Shaft Diameter . . . . . . . . . . . . . . . . 7 - 5 Formula to Determine Belt Length . . . . . . . . . . . . . . . . . . 7 - 5 Gear Reducer Formulas . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 - 6 Motor Torque Formulas . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 - 7 Adjusting Belt Tension . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 - 8 V - Belts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 - 9 V - Belt / Motor Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 - 9 Standard “ V � Belt Lengths . . . . . . . . . . . . . . . . . . . . . . . . 7 - 10 Horsepower Capacities of Light 4 - Ply Nylon - Stitched Belts . . . . . . . . . . . . . . . . . . . . . . . . . . 7 - 12 Horsepower Capacities of Medium 4 - Ply Nylon - Stitched Belts . . . . . . . . . . . . . . . . . . . . . . . . . . 7 - 12 Horsepower Capacities of Heavy 4 - Ply Nylon - Stitched Belts . . . . . . . . . . . . . . . . 7 - 13 xvii
Page: 12

TOC MotorPal DEWALT 7 / 25 / 05 3 : 15 PM Page xviii Horsepower Capacities of Medium 4 - Ply Woven Endless Cotton Belts . . . . . . . . . . . . . . . 7 - 13 Horsepower Capacities Per Inch of Width of Regular Single - Ply Dacron Belts . . . . . . . . . . . . . . . 7 - 14 Horsepower Capacities Per Inch of Width of Medium Single - Ply Dacron Belts . . . . . . . . . . . . . . 7 - 15 Horsepower Capacities Per Inch of Width of Light Single - Ply Dacron Belts . . . . . . . . . . . . . . . . . 7 - 16 3 � 8 " Diameter Wound Horsepower Capacities of Endless Round Belts . . . . . . . . . . . . . . . . . . . . . . . . . . 7 - 17 Correction Factors for Small Pulley Angles of Contact Less Than 180º . . . . . . . . . . . . . . . . . . . . . . . 7 - 18 Correction Factors for Belt Variations . . . . . . . . . . . . . . . 7 - 19 1 � 4 " Horsepower Capacities of Diameter Braided Endless Round Belts . . . . . . . . . . . 7 - 20 3 � 8 " Horsepower Capacities of Diameter Braided Endless Round Belts . . . . . . . . . . . 7 - 21 9 � 16 " Horsepower Capacities of Diameter Wound Endless Round Belts . . . . . . . . . . . . 7 - 22 Method of Connection : Adjustable - Speed Drive . . . . . . 7 - 23 Method of Connection : Constant - Speed Drive . . . . . . . 7 - 24 Maximum Horsepower : Two - Bearing Motors with Chain Drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 - 26 Horsepower Limits : Two - Bearing Motors with Belt Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 - 26 Speed Limitations : Belt , Gear , and Chain Drives . . . . . . 7 - 27 xviii
Page: 13

02 MotorPal DEWALT 7 / 13 / 05 3 : 05 PM Page 16 REVERSING SPLIT - PHASE MOTORS Run windings T Section 1 1 T 2 T 8 L 1 Start windings L 2 T 5 T 3 T Run 4 windings Start switch Section 2 Four - pole dual - voltage split - phase motor — counterclockwise Run windings Section 2 T 1 T 4 T 8 L 1 Start T 5 windings L 2 T 3 Run T 2 windings Section 1 Start switch Four - pole dual - voltage split - phase motor — clockwise 2 - 16
Page: 14

03 MotorPal DEWALT 7 / 13 / 05 3 : 03 PM Page 53 MOTOR CONTROL CIRCUITS ( cont . ) L L L L L L 1 2 3 1 2 3 Start Start X Stop Stop 3 3 2 2 T T T T T T 1 2 3 1 2 3 Motor 1 Motor 2 L L 1 2 Start O . L . Stop 2 3 M 1 Start O . L . Stop 2 3 M 1 M 2 M 2 Control circuit is connected only to the lines of Motor 1 . Starters arranged for sequence control of a conveyor system . 3 - 53
Page: 15

05 MotorPal DEWALT 7 / 13 / 05 3 : 04 PM Page 24 MOTOR OVERLOADS The term overload refers to a condition that results from applying an excessive load to a motor . Motors try to drive the connected load when power is applied . Obviously , the larger the load , the more power is required to drive the load . Every motor that is manufactured has a rated limit to the load they are able to drive . For example , a 10 HP , 460 V , 3φ motor should draw no more than 14 amps of current . If a motor begins to draw more than its rating , overloading will begin . Current readings must be taken to determine if an overload problem exists . The chart below illustrates meter readings and their relationship to the motor’s listed rating from the nameplate . Meter Readings Current Rating Fully Loaded Underloaded Overloaded Of Motor Motor Motor Motor 20 A 20 A 12 A 22A Nameplate 95 to 105 % 0 to 95 % 105 % + Rating of Rating of Rating of Rating The even blackening of all of the motor windings occurs when a motor has failed due to overloading . This even discoloration is due to the slow destruction of the windings over a long time period . Normally , no visible damage to the insulation of the motor can be detected . If a motor is protected properly , overloads should not become a problem . Using correctly - sized heaters in the motor starter will assure that an overload is removed from the motor before any damage occurs . 5 - 24